Сторінка 5
... Traps .. CHAPTER VI . The Making of Complete Elevations of Plumbing Systems . CHAPTER VII . Practice Drawings for Parts of Plumbing Work in a Residence . CHAPTER VIII . The Drawing of Fixtures on a Scale CHAPTER IX . Practice Exercises ...
... Traps .. CHAPTER VI . The Making of Complete Elevations of Plumbing Systems . CHAPTER VII . Practice Drawings for Parts of Plumbing Work in a Residence . CHAPTER VIII . The Drawing of Fixtures on a Scale CHAPTER IX . Practice Exercises ...
Сторінка 15
... trap , waste , and back air for the lavatory are shown plain , which is inconsistent with the appearance of the fixture itself . The back air pipe running straight up from the crown of the pipe looks as if it must break through the bowl ...
... trap , waste , and back air for the lavatory are shown plain , which is inconsistent with the appearance of the fixture itself . The back air pipe running straight up from the crown of the pipe looks as if it must break through the bowl ...
Сторінка 17
... trap , Fig . 15 , draw in the straight parts of the trap first , and put in the curves next . Do not get the three branches of the trap too far apart , as shown in the incorrect sketches , and the middle part should the center to either ...
... trap , Fig . 15 , draw in the straight parts of the trap first , and put in the curves next . Do not get the three branches of the trap too far apart , as shown in the incorrect sketches , and the middle part should the center to either ...
Сторінка 20
... trap and its back air pipe would not have shown broadside to us , as Fig . 19 represents . Therefore , in this work , the layout of the work should be sized up first , and such an elevation chosen as will show the work to best advantage ...
... trap and its back air pipe would not have shown broadside to us , as Fig . 19 represents . Therefore , in this work , the layout of the work should be sized up first , and such an elevation chosen as will show the work to best advantage ...
Сторінка 21
... Trap Scale 1⁄4 - inch to I foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting ...
... Trap Scale 1⁄4 - inch to I foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 3rd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory lines of pipe main drain main line main stack main trap main Vent Line mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines tee square thread tical tion Toilet Room Stack triangle valve vertical lines Wash Trays waste water closet wrought iron