Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 1-5 із 12
Сторінка 21
... foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting , etc. , tha : he is usually ...
... foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting , etc. , tha : he is usually ...
Сторінка 22
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
Сторінка 23
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
Сторінка 74
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
Сторінка 76
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 15 MECHANICAL DRAWING FOR PLUMBERS 76.
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 15 MECHANICAL DRAWING FOR PLUMBERS 76.
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 3rd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory lines of pipe main drain main line main stack main trap main Vent Line mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines tee square thread tical tion Toilet Room Stack triangle valve vertical lines Wash Trays waste water closet wrought iron