Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 1-5 із 16
Сторінка 7
... better than to take up the study of mechanical drawing , at least so far as it concerns the laying out of plumbing and heating work . A knowledge of the subject is valuable , not only to the man who is conducting a business and uses his ...
... better than to take up the study of mechanical drawing , at least so far as it concerns the laying out of plumbing and heating work . A knowledge of the subject is valuable , not only to the man who is conducting a business and uses his ...
Сторінка 20
... better view than the other . If the elevation had been taken from the end of the sink , it will be noticed that the waste and vent lines would have come one in front of the other instead of side by side as the front elevation shows ...
... better view than the other . If the elevation had been taken from the end of the sink , it will be noticed that the waste and vent lines would have come one in front of the other instead of side by side as the front elevation shows ...
Сторінка 21
... better advantage , with less cutting , etc. , tha : he is usually able to do under present existing and undesirable conditions . In comparing these floor plans with the cellar plan , 21 CHAPTER IV Drawings of Plumbing in an Ordinary ...
... better advantage , with less cutting , etc. , tha : he is usually able to do under present existing and undesirable conditions . In comparing these floor plans with the cellar plan , 21 CHAPTER IV Drawings of Plumbing in an Ordinary ...
Сторінка 23
... better still , to change the layout and lo- cate the stacks in their proper positions on the several floors . The drawing of a cellar plan , with the pipes showing , as we submit in Fig . 20 , is especially desirable work for the be ...
... better still , to change the layout and lo- cate the stacks in their proper positions on the several floors . The drawing of a cellar plan , with the pipes showing , as we submit in Fig . 20 , is especially desirable work for the be ...
Сторінка 27
... better avoid after comparing wrong construc- tions with correct . The common quar- ter bend is a compact fitting as No. 1 will show , and the mistake often made is in giving it the long sweep shown in No. 2 , although there are special ...
... better avoid after comparing wrong construc- tions with correct . The common quar- ter bend is a compact fitting as No. 1 will show , and the mistake often made is in giving it the long sweep shown in No. 2 , although there are special ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 3rd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory lines of pipe main drain main line main stack main trap main Vent Line mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines tee square thread tical tion Toilet Room Stack triangle valve vertical lines Wash Trays waste water closet wrought iron