The back air pipe running straight up from the crown of the pipe looks as if it must
break through the bowl and marble slab , while the lines which are dotted show
that this pipe in reality runs behind the marble back . It should be noted that ...
The back air pipe running straight up from the crown of the pipe looks as if it must
break through the bowl and marble slab , while the lines which are dotted show
that this pipe in reality runs behind the marble back . It should be noted that ...
Сторінка 20
If the elevation had been taken from the end of the sink , it will be noticed that the
waste and vent lines would have come one in front of the other instead of side by
side as the front elevation shows , and the trap and its back air pipe would not ...
If the elevation had been taken from the end of the sink , it will be noticed that the
waste and vent lines would have come one in front of the other instead of side by
side as the front elevation shows , and the trap and its back air pipe would not ...
Сторінка 36
38 , to which we wish to call attention , is the manner in which the main line of
back air for the bathroom stack is shown . In Fig . 34 of the previous article , it is
shown directly in line with , and in front of the main stack , and this is of course the
...
38 , to which we wish to call attention , is the manner in which the main line of
back air for the bathroom stack is shown . In Fig . 34 of the previous article , it is
shown directly in line with , and in front of the main stack , and this is of course the
...
Сторінка 44
In this case , we might have dotted the waste to the floor , and the back air to the
partition , but have preferred to show it in the way that it appears , which we
believe will be clear enough for all purposes . There are many places where it is
...
In this case , we might have dotted the waste to the floor , and the back air to the
partition , but have preferred to show it in the way that it appears , which we
believe will be clear enough for all purposes . There are many places where it is
...
Сторінка 46
fers to use this fitting in the drawing of work in which water pipe is to be drawn ,
branch taken off the main back air where it offsets , comes out of the tee straight
toward us , and then bends off at an angle of 45 deg . , then comes out straight ...
fers to use this fitting in the drawing of work in which water pipe is to be drawn ,
branch taken off the main back air where it offsets , comes out of the tee straight
toward us , and then bends off at an angle of 45 deg . , then comes out straight ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
able advantage angle appear arrow back air Bath bath room believe better branch building carried cellar plan CHAPTER clear clearly connection consider course curves desired difficult direction distance dotted double drain drainage drawing drawn elevation entirely exercises fact figure fittings fixtures floor plans foot front give given horizontal hubs illustrations inch instance Kitchen knowledge larger latter Lavatory laying lead length light lines lines of pipe looking manner method necessary noticed object obtained parallel perspective piece pipe plain plumber plumbing position practice preceding present readers reference represents residence roof Room scale seen serve shading shown in Fig side simply sink sketch space square stack straight lines student taken tion trap triangle usually vent vertical wall waste