" All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in any case be smaller than No. 18 B. & S., No. "
Practical Dynamo Building: With Detail Drawings and Instructions for Winding - Сторінка 97
автори: La Motte C. Atwood - 1893 - 143 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...the fastenings or motion of the fixtures. 3. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in any rase be smaller than No. 1(5 B. and S., No. 18 BWG. or No. 3 ESG 4. All burrs or fins must be removed...
Повний перегляд - Докладніше про цю книгу

A Hand-book of Wiring Tables for Arc, Incandescent Lighting, and Motor Circuits

Arthur Eugene Watson - 1892 - 118 стор.
...fusible strip or wire should be incombustible and moisture-proof, and so constructed that an arc cannot be maintained across its terminals by the fusing of...possible "contact" between wire and fixture, and for "short-circuit," before current is turned on. 53. The tendency to condensation within the pipes or...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...the fastenings or motion of the fixture. (d) All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded,...must not in any case be smaller than No. 18 B. & S., No. 20 BWG, No. 3 BSG (e) All burrs or fins must be removed before the conductors arc drawn into a...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...the fastenings, or motion of the fixtures. 3. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in any case be smaller than No. 16 B. & S., No. 1 8 BWG', or No. 3 ESG 4. All burrs or fins must be removed before the conductors are...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...the fastenings, or motion of the fixtures. 3. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in any case be smaller than No. 16 B. & S., No. 18 BWG. or No. 3 ESG 4. All burrs or fins must be removed before the conductors are...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...the fastenings or motion of the fixture. (d) All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in jicy case be smaller than No. 18 B. & S., No. 20 BWG, No. 2 ESG (e) All burrs or fins must be removed...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...the fastenings or motion of the fixture. d. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded,...must not in any case be smaller than No. 18 B. & S., No. 20 BWG, or No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...the fastenings or motion of the fixtures 3. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not In any case be smaller than No. 16 B. & 8., No. 18 BWQ, or No. 8 E. 8. Q. 4. All burn or fins must be removed before the conductors...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...the fastenings, or motion of the fixtures. 3. All conductors for fixture work must have a waterproof insulation that is durable and not easily abraded, and must not in any case be smaller than No. 10 B. & S.. No. 18 BWG. or No. :} ESG 4. All burrs or fins must be removed before the conductors are...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...the fastenings or motion of the fixture. d. All conductors for fixture-work must have a waterproof insulation that is durable and not easily abraded,...must not in any case be smaller than No. 18 B. & S., No. 20 BWG, No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into a fixture....
Повний перегляд - Докладніше про цю книгу