The Architect's and Builder's Pocket-book of Mensuration, Geometry ...: Strength and Stability of Foundations ... Etc ... Statistics and Tables Relating to Carpentry, Masonry, Drainage ... EtcWiley, 1892 - 911 стор. |
З цієї книги
Результати 1-5 із 67
Сторінка viii
... Fire Protection of Mills , " by C. J. H. Woodbury , in- spector for the Factory Mutual Fire Insurance Companies . John Wiley & Sons , publishers , New York . " House Drainage and Water Service , " by James vlii PREFACE .
... Fire Protection of Mills , " by C. J. H. Woodbury , in- spector for the Factory Mutual Fire Insurance Companies . John Wiley & Sons , publishers , New York . " House Drainage and Water Service , " by James vlii PREFACE .
Сторінка xv
... FIRE - PROOF FLOORS . MILL CONSTRUCTION · CHAPTER XXIV . CHAPTER XXV . 422 • 425 0 MATERIALS AND METHODS OF FIRE - PROOF CONSTRUCTION FOR BUILDINGS CHAPTER XXVI . WOODEN ROOF - TRUSSES , WITH DETAILS CHAPTER XXVII . IRON ROOFS AND ROOF ...
... FIRE - PROOF FLOORS . MILL CONSTRUCTION · CHAPTER XXIV . CHAPTER XXV . 422 • 425 0 MATERIALS AND METHODS OF FIRE - PROOF CONSTRUCTION FOR BUILDINGS CHAPTER XXVI . WOODEN ROOF - TRUSSES , WITH DETAILS CHAPTER XXVII . IRON ROOFS AND ROOF ...
Сторінка 181
... fire - clay tiles . 6 . ordinary clay tiles .. Porous terra - cotta tiles .. Mortars . ( In -inch joints , 3 months old , tons per square foot . ) Portland cement , 1 to 4 . Rosendale cement , 1 to 3 . Lime mortar . best .. Best ...
... fire - clay tiles . 6 . ordinary clay tiles .. Porous terra - cotta tiles .. Mortars . ( In -inch joints , 3 months old , tons per square foot . ) Portland cement , 1 to 4 . Rosendale cement , 1 to 3 . Lime mortar . best .. Best ...
Сторінка 437
... fire , without throwing the wall . It also gives the weight a good bearing on the wall . CHAPTER XXIII . FIRE - PROOF FLOORS . THE term. FIG . 5. - GOETZ JOIST HANGER . FIG . 6. - DUPLEX BRICK WALL 1 Hatfield's Transverse Strains , p ...
... fire , without throwing the wall . It also gives the weight a good bearing on the wall . CHAPTER XXIII . FIRE - PROOF FLOORS . THE term. FIG . 5. - GOETZ JOIST HANGER . FIG . 6. - DUPLEX BRICK WALL 1 Hatfield's Transverse Strains , p ...
Сторінка 438
... FIRE - PROOF FLOORS . THE term " fire - proof floor " is here understood to mean a floor constructed of fire - proof material , supported on or betwe n iron or steel beams or girders , or fire - proof walls , and entirely protecting the ...
... FIRE - PROOF FLOORS . THE term " fire - proof floor " is here understood to mean a floor constructed of fire - proof material , supported on or betwe n iron or steel beams or girders , or fire - proof walls , and entirely protecting the ...
Зміст
158 | |
167 | |
187 | |
194 | |
206 | |
233 | |
242 | |
290 | |
297 | |
329 | |
371 | |
383 | |
401 | |
410 | |
422 | |
609 | |
617 | |
620 | |
623 | |
633 | |
650 | |
716 | |
760 | |
769 | |
825 | |
845 | |
1 | |
22 | |
Інші видання - Показати все
Загальні терміни та фрази
angles arch Architect axis bars beam bending-moment boiler Boston brick Bridge building cast-iron ceiling cement cent centre of gravity chimney column concrete construction Cosin Sine Cosin cube cubic feet cubic foot deflection depth Diam diameter dimensions distance distributed load draw equal factor of safety feet 6 inches fire-proof flange floor formula furnace girder given heat I-beams inches thick iron joint joist length masonry material Mead & White metal mineral wool moment of inertia mortar Multiply pieces pier pipe plaster plates Portland cement pounds per square pressure purlins radiator radius rafter resistance rivets roof safe load shown in Fig side Sine Cosin Sine span square feet square foot square inch steam steel stone strain strength strut surface terra-cotta tile timber truss vertical voussoirs wall Weight per foot width wire wrought-iron Z-BAR
Популярні уривки
Сторінка 26 - Square Measure 144 square inches = 1 square foot 9 square feet = 1 square yard...
Сторінка 4 - Multiply the divisor, thus augmented, by the last figure of the root, and subtract the product from the dividend, and to the remainder bring down the next period for a new dividend.
Сторінка 125 - Force is that which changes, or tends to change, the state of rest or motion of the body acted upon.
Сторінка 679 - Must have a switch and a cut-out for each wire between the underground conductors and the interior wiring when the two parts of the wiring are connected. These "switches and fuses must be placed as near as possible to the end of the underground conduit, and connected therewith by specially insulated conductors, kept apart not less than two and a half inches.
Сторінка 681 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 679 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 684 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing will be approved. e. Must be tested for "contacts...
Сторінка 38 - A Sphere is a solid bounded by a curved surface all points of which are equally distant from a point within called the centre.
Сторінка 720 - Multiply the diameter of the driver by number of its revolutions, and divide the product by the diameter of the driven, the quotient will be the number of revolutions of the driven.
Сторінка 675 - Architects are urged, when drawing plans and specifications, to make provision for the channeling and pocketing of buildings, for electric light or power wires, and...