... ratus and materials from accidental damage by other contractors or otherwise , making good any damage thus occurring at his own expense ; also making good any injury done the building in the performance of his work . He shall be ...
... ratus and materials from accidental damage by other contractors or otherwise , making good any damage thus occurring at his own expense ; also making good any injury done the building in the performance of his work . He shall be ...
Сторінка 42
... ratus and material : direct current , constant potential dy- namo ( s ) ( each ) having a normal capacity of ampères at volts . The ( se ) dynamo ( s ) shall be shunt wound , compound wound or pro- vided with an efficient automatic regu ...
... ratus and material : direct current , constant potential dy- namo ( s ) ( each ) having a normal capacity of ampères at volts . The ( se ) dynamo ( s ) shall be shunt wound , compound wound or pro- vided with an efficient automatic regu ...
Сторінка 52
... ratus and material : of dynamo ( s ) ( each ) having a capacity c . p . , incandescent lamps . The maximum voltage at the terminals of the dynamo ( s ) shall not exceed -- volts at full load . The dynamo ( s ) shall be of the latest and ...
... ratus and material : of dynamo ( s ) ( each ) having a capacity c . p . , incandescent lamps . The maximum voltage at the terminals of the dynamo ( s ) shall not exceed -- volts at full load . The dynamo ( s ) shall be of the latest and ...
Сторінка 58
... ratus and material : constant potential , alternating cur- rent dynamo ( s ) ( each ) having a capacity of c . p . , volt incandescent lamps . The maximum voltage at the terminals of the dynamo ( 58 ELECTRIC LIGHTING SPECIFICATIONS ...
... ratus and material : constant potential , alternating cur- rent dynamo ( s ) ( each ) having a capacity of c . p . , volt incandescent lamps . The maximum voltage at the terminals of the dynamo ( 58 ELECTRIC LIGHTING SPECIFICATIONS ...
Сторінка 63
... ratus and material : 54. Dynamo ( s ) . " A dynamo capacity ELECTRIC LIGHTING SPECIFICATIONS . 63 Switchboard Switchboard Apparatus and Connections Circuits ALTERNATING CURRENT OR DIRECT CURRENT SYSTEM WITH THE PARALLEL SYSTEM OF ...
... ratus and material : 54. Dynamo ( s ) . " A dynamo capacity ELECTRIC LIGHTING SPECIFICATIONS . 63 Switchboard Switchboard Apparatus and Connections Circuits ALTERNATING CURRENT OR DIRECT CURRENT SYSTEM WITH THE PARALLEL SYSTEM OF ...
Інші видання - Показати все
Загальні терміни та фрази
Age money Alternating Current ampère meter apparatus appliances arc lamps armature attached automatic baseframe bidder shall fill bids building c. p. lamps cables candle power capacity carried ceiling cent centre of distribution cleats conductors conduit connections contractor shall furnish cross-arms cuits cut-out boxes cut-outs and switches Direct Current double-pole dynamo or circuit dynamos Trade number erect the following fastened fill out completely fixture foundation(s full load fuses hand regulator incandescent lamps inches incombustible bases installation insulated wire insulation resistance junction boxes knife switch least lightning arresters main wires ments moisture moisture-proof molding necessary non-combustible number of lights number or designation ohms operation outlets pipes placed plant porcelain potential pressure proper protected pulleys purchaser Rating of exciters riser feeder schedule securely set screws shunt Sockets soldered spark arresters specification steam struction switchboard taps three-wire tightened tion tube two-wire voltage voltmeter volts walls waterproof wire smaller