Сховані поля
Книги Книги
" SOCKETS:— a. No portion of the lamp socket exposed to contact with outside objects must be allowed to come into electrical contact with either of the conductors. "
Convention - Сторінка 111
автори: National Electric Light Association. Convention - 1892
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...free from " grounds." 4. The two installations must teat perfectly free of connection with each other. PENDANTS AND SOCKETS. No portion of the lamp socket...from the other conductor by a mechanical separator of carbonisable material, and both surrounded in damp places with a moisture-proof and a non-infltimmable...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...(d) The two installations must test perfectly free from connection with each other. 30. Sockets : (a) No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. (b) In rooms where inflammable gases may exist, or where the atmosphere is damp, the incandescent lamp...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...free from "grounds." 4. The two installations must test perfectly free of connection with each other. Pendants and Sockets. No portion of the lamp socket exposed to contact with outside ohjects must be allowed to come into electrical contact with either of the conductors. CORD PENDANTS—Must...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...test perfectly free from connection with each other. V X. . „.30. SOCKETS— ^ ~s.~ "7 \c, .'.^ a a. No portion of the lamp ^socket< exposed to contact with outside objects nlust be allowed to come into electrical contact with either of the conductors. 6. In rooms where inflammable...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 620 стор.
...The two Installations must test perfectly free of connection with each other. Pendant» and Socket». No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. Cord Pendant». 1. Must be made of conductors, each of which Is composed of several strands Insulated from...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...from " grounds." 4. The two installations must test perfectly free of connection with each other. 143. PENDANTS AND SOCKETS. No portion of the lamp socket...electrical contact with either of the conductors. 144. COKD PENDANTS. 1. Must be made of conductors, each of which is composed of several strand-- insulated...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...The two installations must test perfectly free from connection with each other. 30. SOCKETS: — a. No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. b. In rooms where inflammable gases may exist, or where the atmosphere is damp, the incandescent lamp...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...d. Tho two installations must test perfectly free from connection with each other. 3o. SOCKETS: a. No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. b. In rooms where inflammable gases exist, or where the atmosphere is damp, the incandescent lamp and...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...The two installations must test perfectly free from connection with each other. 30. SOCKETS:— a. No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. b. In rooms where inflammable gases may exist, or where the atmosphere is damp, the incandescent lamp...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...d. The two installations must test perfectly free from connection with each other. 30. SOCKETS : a. No portion of the lamp socket exposed to contact with...electrical contact with either of the conductors. b. In rooms where inflammable gases may exist, or where the atmosphere is damp, the incandescent lamp...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF