Пошук Зображення Карти Play YouTube Новини Gmail Диск Більше »
Увійти
Книги Книги
" Must, for constant-current systems, be provided with an approved hand switch, also an automatic switch that will shunt the current around the . carbons, should they fail to feed properly. "
Convention - Сторінка 103
автори: National Electric Light Association. Convention - 1892
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...partitions, treated as in central stations under like conditions. Lamps and Other Devices. ARC LAMPS—Must be in every case: 1. Carefully isolated from inflammable...insulated from the circuit in all their exposed parts. Incandescent lamps in series circuits, having a maximum potential of 350 volts or over, must be governed...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...with a glass globe surrounding the arc, securely fastened upon a closed base. No broken or cracaed globes may be used. 3. Provided with a hand switch,...provided with a wire netting around the globe and a spark arrester above, to prevent escape of sparks, melted copper or carbon. Incandescent lamps in series...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...with a glass globe surrounding the arc, securely fastened upon a closed base. No broken or cracited globes may be used. 3. Provided with a hand switch,...insulated from the circuit in all their exposed parts. Incandescent lamps in series circuits, having a maximum potential of 350 volts or over, must be governed...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...switch that will shunt the current around the carbons should they fail to feed properly. (d) Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. (c) Must be carefully insulated from the circuit in all their exposed parts. (/) Must be provided with...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...switch, that will shunt the current around the carbons should they fail to feed properly. d. Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. e. Must be carefully insulated from the circuit in all their exposed parts. f. Must be provided with...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...switch, that will shunt the current around the carbons should they fall to feed properly. I. Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. 5. Must be carefully Insulated from the circuit in all their exponed parts. 6. Must be, wbere Inflammable...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...comply with requirements for switches on hanger-boards as laid down in Section g of Rule 13. d. Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. e. Must be carefully insulated from the circuit in all their exposed parts. f. Must be provided with...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...shunt the current around the carbons should they fail to feed properly. (See Definitions.) d. Must be provided with reliable stops to prevent Carbons from falling out in case the clamps become loose. e. Must be carefully insulated from the circuit in all their exposed parts. f. Must be provided with...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...comply with requirements for switches on hanger-boards as laid down in Section g of Rule 13.] d. Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. e. Must be carefully insulated from the circuit in all their exposed parts. / Must be provided with...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 стор.
...shunt the current around the carbons should they fail to feed properly. (See Definitions). d. Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose. e. Must be carefully insulated from the circuit in all their exposed parts. /. Must be provided with...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF