... fuses at junctions of distributing mains with feeding conductors . 3. Separated not less than six inches , where they enter buildings as service conductors , and be provided with a double pole fusible cut - out , as near as possible to ...
... fuses at junctions of distributing mains with feeding conductors . 3. Separated not less than six inches , where they enter buildings as service conductors , and be provided with a double pole fusible cut - out , as near as possible to ...
Сторінка 120
... FUSES must be so proportioned to the conduc- tors they are intended to protect , that they will melt be- fore the ... fuse depends upon the size of the smallest conductor it protects , and not upon the amount of current to be used on ...
... FUSES must be so proportioned to the conduc- tors they are intended to protect , that they will melt be- fore the ... fuse depends upon the size of the smallest conductor it protects , and not upon the amount of current to be used on ...
Сторінка 124
... fuses at the junction between main and service conductors and safety fuses in the secondary circuits where they will not be affected by the heat of the converter . PRIMARY CONDUCTORS . In those cases where it may not be possible to ex ...
... fuses at the junction between main and service conductors and safety fuses in the secondary circuits where they will not be affected by the heat of the converter . PRIMARY CONDUCTORS . In those cases where it may not be possible to ex ...
Сторінка 140
... fuses at the generator , and will put in a 160 or 200 ampere fuse on a machine that is only adapted to carry 130 amperes . I find that the better plan is on a 130 ampere machine to put in a 135 to 140 ampere fuse , and then change it ...
... fuses at the generator , and will put in a 160 or 200 ampere fuse on a machine that is only adapted to carry 130 amperes . I find that the better plan is on a 130 ampere machine to put in a 135 to 140 ampere fuse , and then change it ...
Сторінка 141
... fuses were removed from the converters , and No. 14 copper substituted , simply because they sometimes blew out . Now , a properly placed fuse does not blow out unless there is a cause for it . There is the greatest of danger in not ...
... fuses were removed from the converters , and No. 14 copper substituted , simply because they sometimes blew out . Now , a properly placed fuse does not blow out unless there is a cause for it . There is the greatest of danger in not ...
Інші видання - Показати все
Загальні терміни та фрази
adopted alternating current ammeter amperes apparatus Applause arc lamp arc lights AYER boilers Boston building BURLEIGH candle power CAPTAIN BROPHY carbons cent Chairman charge Chicago circuit conductors connection construction Convention cost cut-out direct current dynamo elec Electric Company Electric Light Association Electric Light Company electric railway engine Executive Committee Exhibition expenses experience fact feet FRANCISCO Frederic Nicholls fuse gentlemen horse car horse power incandescent lamps inches installed insulation interest JUDGE ARMSTRONG Light and Power load machine MASON matter McGill University meeting meter month Montreal motion was carried motor multiple arc National Electric Light operation paper parent companies placed plant pole practice present President question repairs resolution rules Safe Wiring SEELY Station Companies steam street railway supply switch thing three-wire system tion to-day trolley turbine underground voltmeter volts water power York
Популярні уривки
Сторінка 106 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 219 - The chariots shall rage in the streets, they shall jostle one against another in the broad ways : they shall seem like torches, they shall run like the lightnings.
Сторінка 112 - Must not be attached to the outside walls of buildings, unless separated therefrom by substantial insulating supports.
Сторінка 103 - Must, for constant-current systems, be provided with an approved hand switch, also an automatic switch that will shunt the current around the . carbons, should they fail to feed properly.
Сторінка 101 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 100 - Arresters should be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals over systems in such numbers and so located as to prevent ordinary discharges entering (over the wires) buildings connected to the lines.
Сторінка 111 - SOCKETS:— a. No portion of the lamp socket exposed to contact with outside objects must be allowed to come into electrical contact with either of the conductors.
Сторінка 115 - When current for light and power is taken from primary or secondary batteries, the same general regulations must be observed as apply to similar apparatus fed from dynamo generators developing the same difference of potential.
Сторінка 229 - Indian gown, with a sash, silk stockings, and beaver hats men ride in, and carry no other with them, because they escape the wet and dirt, which on horseback they cannot avoid ; whereas, in two or three journeys on horseback, these clothes and hats were wont to be spoiled. Which done, they were forced to have new very often, and that increased the consumption of the manufactures, and the employment of the manufacturers, which travelling in coaches doth no way do.
Сторінка 111 - Must be so suspended that the entire weight of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or rosette, in order that the strain may be taken from the joints and binding screws.