| National Electric Light Association. Convention - 1892 - 458 стор.
...building and join the inside wires. 2. Placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductors. All such junctions must be in plain sight. 3. Constructed with bases... | |
| Frank Eugene Kidder - 1892 - 1032 стор.
...box, readily accessible. (6) Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). (el Must be supported on bases of non-combustible, insulating, moisture-proof material. (d) Must be... | |
| Earle Abbott Merrill - 1892 - 188 стор.
...POLE SAFETY CUT-OUTS— Must be: 2. Placed at every point where a change is made in the size of wires (unless the cut-out in the larger wire will protect the smaller.) This includes all flexible conductors. All such junctions must be in plain sight. 3. Constructed with bases... | |
| Charles M. Davis - 1893 - 162 стор.
...box, readily accessible. b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of noncombustible, insulating, moisture-proof material. d. Must be supplied... | |
| 1894 - 620 стор.
...and join the inside wires. 2. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductora. All euch junctions must be In plain sight. 8. Must be constructed... | |
| Nehemiah Hawkins - 1896 - 568 стор.
...accessible. (See Definitions.) b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). NATIONAL BOARD FIRE UNDERWRITERS. c. Must be supported on bases of non -combustible, insulating, moisture-proof... | |
| Russell Robb - 1896 - 208 стор.
...might be ignited thereby.] 6. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating, moisture-proof material. d. Must be supplied... | |
| Earle Abbott Merrilol - 1896 - 232 стор.
...accessible. (See Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating, moistureproof material. d. Must be supplied... | |
| Earle Abbott Merrill - 1896 - 232 стор.
...accessible. (See Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non- combustible, insulating, moistureproof material. d. Must be supplied... | |
| George H. Kimber - 1896 - 80 стор.
...might be ignited thereby. b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating, moisture-proof material. d. Must be supplied... | |
| |