Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior WiringInternational Textbook Company, 1906 - 550 стор. |
З цієї книги
Результати 1-5 із 100
Сторінка 46
... circuit until probably near the end of the dis- charge , and thus require but a small proportion of the amount of charge required for the main battery . As an aid in deter- mining the state of charge of the end cells , there is usually ...
... circuit until probably near the end of the dis- charge , and thus require but a small proportion of the amount of charge required for the main battery . As an aid in deter- mining the state of charge of the end cells , there is usually ...
Сторінка 48
... circuit , because the E. M. F. of the cells is opposed to that of the line . If I is the charging current , then the resistance of the circuit will be R = E - 2 N I ( 1 ) and this will be practically equal to the amount of resistance ...
... circuit , because the E. M. F. of the cells is opposed to that of the line . If I is the charging current , then the resistance of the circuit will be R = E - 2 N I ( 1 ) and this will be practically equal to the amount of resistance ...
Сторінка 49
... circuits . 47. Charging From Constant - Current Arc Circuit . Sometimes cells are charged from constant - current arc - light circuits , but the practice is dangerous and this source of charging current should never be used if any other ...
... circuits . 47. Charging From Constant - Current Arc Circuit . Sometimes cells are charged from constant - current arc - light circuits , but the practice is dangerous and this source of charging current should never be used if any other ...
Сторінка 66
... circuit while a is passing from one cell to another , auxiliary carbon contacts are carried on the cross - head ... circuit - breakers , etc. have been omitted . An automatic circuit - breaker should be provided in series with the dynamo ...
... circuit while a is passing from one cell to another , auxiliary carbon contacts are carried on the cross - head ... circuit - breakers , etc. have been omitted . An automatic circuit - breaker should be provided in series with the dynamo ...
Сторінка 43
... circuit through the heater coils . There are two armatures and sets of contacts in this lamp , so that the heater circuit is opened in two places . The armatures are suspended loosely from a single point of support to avoid . humming ...
... circuit through the heater coils . There are two armatures and sets of contacts in this lamp , so that the heater circuit is opened in two places . The armatures are suspended loosely from a single point of support to avoid . humming ...
Загальні терміни та фрази
16-candlepower lamps adjusted allowed alternating current alternating-current ammeter amount ampere-hours amperes arc lamps arc-light armature arrangement battery booster burn calculations candlepower carbon carry cells cent center of distribution charging circular mils conductors conduit connected in series constant constant-current constant-potential copper core cut-out direct current direct-current discharge distance drop dynamo efficiency electric enclosed arc enclosed-arc lamp feeders feet filament fixture fuse globe ground hence illumination incandescent lamps inch installed insulation large number light load lower machine magnet mains method motors necessary Nernst lamp number of lamps ohms open-arc lamp operated ordinary outlet pipe placed plates plug porcelain positive pressure primary reactance regulation resistance rheostat secondary series circuit short circuit shown in Fig shows shunt coil side single-phase socket station supplied switch switchboard temperature terminals three-phase three-wire system tion transformer tube two-wire Underwriters usually voltage voltmeter volts wattmeter watts
Популярні уривки
Сторінка 3 - The American Institute of Electrical Engineers; The American Society of Mechanical Engineers; The American Society of Civil Engineers; The American Society of Mining and Metallurgical Engineers; and The American Society for Testing Materials.
Сторінка 65 - Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S.
Сторінка 10 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 64 - Insulation Resistance — The wiring in any building must test free from grounds; ie, the complete installation must have an insulation between conductors and between all conductors and the ground (not including attachments, sockets, receptacles, etc.) of not less than the following: Up to 5 amperes 4,000,000 ohms...
Сторінка 68 - ... b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller.
Сторінка 27 - Circuitbreakers must not be set more than 30 per cent. above the allowable carrying capacity of the wire, unless a fusible cut-out is also installed in the circuit.
Сторінка 12 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 34 - Rigid supporting requires under ordinary conditions, where wiring along flat surfaces, supports at least every four and one-half feet. If the wires are liable to be disturbed, the distance between supports should be shortened. In buildings of mill construction, mains of No.
Сторінка 56 - The object of a tube or conduit is to facilitate the insertion or extraction of the conductors to protect them from mechanical injury and, as far as possible, from moisture. Tubes or conduits are to be considered merely as raceways, and are not to be relied upon for insulation between wire and wire, or between the wire and the ground.
Сторінка 12 - Must be separated from contact with walls, floors, timbers or partitions through which they may pass by non-combustible, non-absorptive, insulating tubes, such as glass or porcelain, except at outlets where approved flexible tubing is required.