" XIV, which may be used for all pressures below 10 pounds, gives for a 3J-inch pipe 100 feet long, a capacity of 18.3 pounds for the above conditions. Looking in Table XVI, we find the correction factor for 450 feet to be .47. Then 18.3 X .47 = 8.6 pounds,... "
Heating and Ventilation: A Working Manual of Approved Practice in the ... - Сторінка 61
автори: American School of Correspondence, Chicago, Charles Lincoln Hubbard - 1908 - 221 стор.
Повний перегляд - Докладніше про цю книгу

Heating, ventilating, plumbing

American School (Chicago, Ill.) - 1903 - 380 стор.
...involving the use of tables X, XI and XII in combination are quite common in practice. The following shows the method of calculation : What size of pipe will...pressure of 80 pounds and' a drop of 5 pounds? Table XII gives the factor for 800 feet as .35 and table XI that for 80 pounds pres90 sure and 5 pounds drop...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 12

American School (Chicago, Ill.) - 1906 - 588 стор.
...involving the use of tables X, XI and XII in combination are quite common in practice. The following shows the method of calculation : What size of pipe will...pressure of 80 pounds and a drop of 5 pounds? Table XII gives the factor for 800 feet as .35 and table XI that for 80 pounds pres90 sure and 5 pounds drop...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School of Correspondence at Armour Institute of Technology, Chicago - 1907 - 460 стор.
...involving the use of tables X, XI and XII in combination are quite common in practice. The following shows the method of calculation : What size of pipe will...pressure of 80 pounds and a drop of 5 pounds? Table XII gives the factor for 800 feet as .35 and table XI that for 80 pounds pressure and 5 pounds drop...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: Heating and ventilation ...

1909 - 500 стор.
...pounds for the above conditions. Looking in Table XVI, we find the correction factor for 450 feet to be .47. Then 18.3 X .47 = 8.6 pounds, the quantity...factor for 800 feet as .35, and Table XV, that for 80 pounds pressure and 5 pounds drop, as 2.09. Then 90 — — — = 123, which is the equivalent quantity...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A General Reference Work on Steam Boilers ..., Том 5

Louis Derr - 1909 - 460 стор.
...pounds for the above conditions. Looking in Table XVI, we find the correction factor for 450 feet to be .47. Then 18.3 X .47 = 8.6 pounds, the quantity...distance of 800 feet, with an initial pressure of 80 p&unds and a drop of 5 pounds? Table XVI gives the factor for 800 feet as .35, and Table XV, that for...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Heating, Plumbing and Sanitation: Heating and ventilation ...

1909 - 444 стор.
...common in practice. The following example will show the method of calculation: What size of pipo \vill be required to deliver 90 pounds of steam per minute a distance of S00 feet, with an initial pressure of 80 pounds and a drop of 5 pounds? Table XVI gives the factor...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture: Heating. Ventilating. Plumbing

1912 - 552 стор.
....47 = 8.6 pounds, the quantity of steam which will be discharged if the pipe is 450 feet longExamples involving the use of Tables XIV, XV, and XVI in combination,...distance of 800 feet, with an initial pressure of SO pounds and a drop of 5 pounds? Table XVI gives the factor for 800 feet as .35, and Table XV, that...
Повний перегляд - Докладніше про цю книгу

Power, Heating and Ventilation ...: Combined power and heating plants

Charles Lincoln Hubbard - 1915 - 428 стор.
...90 .05 200 0.70 475 0.46 1000 0.31 100 .00 225 0.66 500 0.45 no 0.95 250 0.63 550 0.42 Example. — What size of pipe will be required to deliver 90 pounds...pressure of 80 pounds and a drop of 5 pounds? Table XLIII. gives the factor for 800 feet as 0.35 and Table XLII. that for SO pounds pressure and 5 pounds...
Повний перегляд - Докладніше про цю книгу

Power, Heating and Ventilation ...: Combined power and heating plants

Charles Lincoln Hubbard - 1915 - 428 стор.
...650 700 750 800 850 900 950 1000 Factor. 0.40 0.39 0 37 0.36 0.35 0.34 0 33 0.32 0.31 Example.—What size of pipe will be required to deliver 90 pounds...pressure of 80 pounds and a drop of 5 pounds ? Table XLIII. gives the factor for 800 feet as 0.35 and Table XLII. that for 80 pounds pressure and 5 pounds...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry, and Building: A General ..., Том 10

1916 - 652 стор.
....47 = 8.6 pounds, the quantity of steam which will be discharged if the pipe is 450 feet longExamples involving the use of Tables XIV, XV, and XVI in combination,...factor for 800 feet as .35, and Table XV, that for 80 pounds pressure and 5 pounds drop, as 2.09. Then 90 -— — — = 123, which is the equivalent...
Повний перегляд - Докладніше про цю книгу