Popular Hand Book for Cement and Concrete Users: A Comprehensive and Popular Treatise on the Principles Involved and Methods Employed in the Design and Construction of Modern Concrete Work ...Norman W. Henley Publishing Company, 1911 - 430 стор. |
З цієї книги
Результати 1-5 із 58
Сторінка 6
... equal to 21⁄2 to 3 times the volume of the lime . In slaking lime , it is important that enough water be added , but not too much . If too much is added , the slaked lime is reduced . to a semi - fluid condition . If not enough , the ...
... equal to 21⁄2 to 3 times the volume of the lime . In slaking lime , it is important that enough water be added , but not too much . If too much is added , the slaked lime is reduced . to a semi - fluid condition . If not enough , the ...
Сторінка 36
... equal , a coarse sand containing a large percentage of coarse particles is far superior to a fine sand in which few coarse particles are present . The best sand is that which , when mixed with cement and water in the required ...
... equal , a coarse sand containing a large percentage of coarse particles is far superior to a fine sand in which few coarse particles are present . The best sand is that which , when mixed with cement and water in the required ...
Сторінка 41
... equal if not stronger . In construction work where tensile or other stresses are to be cared for , as may occur in reinforced concrete , crushed gravel should be used . The cement will adhere more readily to crushed than to the rounded ...
... equal if not stronger . In construction work where tensile or other stresses are to be cared for , as may occur in reinforced concrete , crushed gravel should be used . The cement will adhere more readily to crushed than to the rounded ...
Сторінка 66
... equal to the required width of the wall is placed beside the wire , where it is left until the concrete reaches that height , after which it is removed . Wired forms are much more secure than those which are merely braced . They possess ...
... equal to the required width of the wall is placed beside the wire , where it is left until the concrete reaches that height , after which it is removed . Wired forms are much more secure than those which are merely braced . They possess ...
Сторінка 94
... equal quantity of sifted marble dust with setting stuff and using this as a final coat . Ordinary finish is greatly improved by substituting a part of marble , alabaster , or gypsum dust , equal in bulk to half the sand generally used ...
... equal quantity of sifted marble dust with setting stuff and using this as a final coat . Ordinary finish is greatly improved by substituting a part of marble , alabaster , or gypsum dust , equal in bulk to half the sand generally used ...
Інші видання - Показати все
Загальні терміни та фрази
50 cents abutment acid aggregate applied arch asphalt barrel bars bending bottom brick bridge broken stone building carrying cent centre chapter coat color columns compression compressive stress concrete blocks consists construction cost cracks crete cubic cubic foot depth diameter employed engineer face feet filled finish floor forms formula foundation girders gravel grout gypsum hardening horizontal hydraulic lime inches lath lime load machine manufacture masonry material metal method mixer mixing mixture mortar mould O'CONOR SLOANE obtained ornamental pile pipe placed plaster plaster of Paris Portland cement posts practical pressure Price proportions reinforced concrete reinforced-concrete removed resistance retaining walls rods Rule sand sewer shear slab slaked lime space span steel stirrups strength stress structure stucco surface tamped tanks tensile stresses tension tests tile trowel tunnel vertical waterproofing weight wire wooden
Популярні уривки
Сторінка 25 - Pats of neat cement about three inches in diameter, one-half inch thick at the center, and tapering to a thin edge, shall be kept in moist air for a period of twenty-four hours.