Пошук Зображення Карти YouTube Новини Gmail Диск Календар Більше »
Увійти
Книги Книги 1 - 10 з 20 у be covered with moisture-proof material. The object of a tube or conduit is to facilitate....
" be covered with moisture-proof material. The object of a tube or conduit is to facilitate the insertion or extraction of the conductors, to protect them from mechanical injury, and as far as possible, from moisture. Twin tube conductors must not be separated... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 127
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

The Electrical Review, Том 8

1891
...Subject to mechanical injury by saws, chisels, or nuk 6. Depended upon for insulation. The conductors a covered with moisture-proof material. The object of a tube or conduit is to facilitate tha in extraction of the conductors, to protect them from : injury, and, as far as possible, from moisture....
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892
...current of more than io amperes is expected. 6. Depended upon for insulation. The conductors should be covered with moisture-proof material. The object...or similar material, but by cotton or other readily carbonizable substance. Conductors passing through walls or ceilings must be encased in a suitable...
Повний перегляд - Докладніше про цю книгу

Electricity as a Fire Hazard ...

W. J. Jenks - 1894 - 73 стор.
...present rules of the underwriters set forth that the "object of a tube or conduit" for interior wiring "is to facilitate the insertion or extraction of the...mechanical injury, and as far as possible from moisture." It is a serious question for the insurance inspector to determine whether there is any method now practiced...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 222 стор.
...g. Conduits must extend at least one inch beyond the finished surface of walls or ceilings until the *The object of a tube or conduit is to facilitate...mechanical injury, and, as far as possible from moisture. Tubes or conduits are to be considered merely as raceways, and are not to be relied on for insulation...
Повний перегляд - Докладніше про цю книгу

Convention, Том 19

National Electric Light Association. Convention - 1896
...conveying water or fluid. According to the standard rules (National Board of Fire Underwriters, 1896,) the object of a tube or conduit is to facilitate the...mechanical injury, and, as far as possible, from moisture. Tubes or conduits are to be considered merely as raceways, and are not to be relied on for insulation...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 183 стор.
...given on page 80 is not necessarily correct for all these special conditions. 22. Interior Conduits: [The object of a tube or conduit is to facilitate...conductors, to protect them from mechanical injury, and, so far as • possible, from moisture. Tubes or conduits are to be considered merely a« raceways,...
Повний перегляд - Докладніше про цю книгу

The What, How, and why of Church Building

George W. Kramer - 1897 - 234 стор.
...installation, a tube or conduit is used to facilitate the insertion or extraction of conductors and to protect them from mechanical injury and as far as possible from moisture, and are to be considered as conduits or raceways only, and not relied on for insulation. All conduits...
Повний перегляд - Докладніше про цю книгу

Transactions, Том 14

American Institute of Electrical Engineers - 1898
...of the fastenings or motion of the fixture. 25. Interior Conduits{See also Nos. 34 n to a, and 41.) The object of a tube or conduit is to facilitate the...mechanical injury and as far as possible, from moisture. Tubes or conduits are to be considered merely as raceways, and are not to be relied upon for insulation...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers

American Society of Mechanical Engineers - 1898
...of the fastenings or motion the fixture. ¿. INTERIOR CoNDUITs(&e aLso IQ'o8. 24 it to q, and 41.) The object of a tube or conduit is to facilitate the Insertion or extraction of o conductors, to prevent them from mechanical injury, and, as far as possible, ¿m moisture. Tubes...
Повний перегляд - Докладніше про цю книгу

Minutes of Proceedings of the Institution of Civil Engineers, Том 143

Institution of Civil Engineers (Great Britain) - 1901
...of different circuits must not be drawn in the same conduit, unless special permission is granted. " The object of a tube or conduit is to facilitate the...mechanical injury, and, as far as possible, from moisture. Tubes or conduits are to be considered merely as raceways, and are not to be relied upon for insulation...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити файл PDF