| National Electric Light Association. Convention - 1892 - 458 стор.
...where the overhead or underground conductors enter a building and join the inside wires. 2. Placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductors. All such junctions must be in plain... | |
| Richard Henry Pierce - 1896 - 234 стор.
...melted fuse metal coming in contact with any substance which might be ignited thereby. b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). ci. Must be supplied with a plug (or other device for inclosing the fusible... | |
| Nehemiah Hawkins - 1896 - 568 стор.
...plain sight or enclosed iu an approved box, readily accessible. (See Definitions.) b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). NATIONAL BOARD FIRE UNDERWRITERS. c. Must be supported on bases of non -combustible,... | |
| Russell Robb - 1896 - 208 стор.
...fuse metal's coming in contact with any substance which might be ignited thereby.] b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out hi the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating,... | |
| American Institute of Electrical Engineers - 1898 - 716 стор.
...with the name of the maker and current and voltage for which the device is designed. c. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). d. In places such as upper decks, holds, cargo spaces and fire rooms, a... | |
| International Correspondence Schools - 1901 - 630 стор.
...building, the cutout required by this section must be placed so as to protect it. b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller]. This (b) means unless the current... | |
| 1901 - 618 стор.
...mounted on porcelain knobs. nioiiiiii i<- Cut-Outs (Fuses and Circuit-Breakers) Ib. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller). a. Must be placed on all service... | |
| Horatio Alvah Foster - 1902 - 1986 стор.
...readily accessible. They must not be placed iu the canopies or shells of fixtures, 6. Must be placed at every point where a change is made in the size of wire [unless the cutout in the larger wire will protect the smaller (see No. 16)]. e. Must be provided... | |
| 1902 - 742 стор.
...building, the cutout required by this section must be placed so as to protect it. b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller]. This (/;) means unless the current... | |
| Dugald Caleb Jackson - 1902 - 568 стор.
...the rated carrying capacity of the smallest wire which they protect. It is customary to place fuses at every point where a change is made in the size of wire, even where small fixtures or drop cords are attached to the tap lines, and not more than a dozen... | |
| |