" clearly understood that the size of the fuse depends upon the size of the smallest conductor it protects, and not upon the amount of current to be used on the circuit. Below is a table showing the safe carrying capacity of conductors of different sizes... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 129
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...piece of moulding than when bare and exposed to the air, when the heat is rapidly radiated. It must be clearly understood that the size of the fuse depends...conductors of different sizes in Birmingham, Brown & Sharp, and Edison gauges, which must be followed in the placing of interior conductors. BIRMINGHAM....
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...maximum safe-carrying capacity of the wire is exceeded. 25. TABLE OF CAPACITY OF WIRES:—It must be clearly understood that the size of the fuse depends...used on the circuit. Below is a table showing the safe-carrying capacity of conductors of different sizes in Brown & Sharpe gauge, which must be followed...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...TABL.E OF CAPACITY OF WIRES : BROWN ft SHARPS WIRE QUAGS '3. & •?. wa) WIRING RULES AND REQUIREMENTS. and not upon the amount of current to be used on the circuit. Below is a table showing the safe-carrying capacity of conductors of different sizes in Brown & Sharpe gauge, which most be followed...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...are supposed, however, to be low enough to prevent this. 25. Table of Capacity of Wires : It must be clearly understood that the size of the fuse depends upon the size of the sniallest conductor it protects, and not upon the amount of current to be used on the circuit. Below...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1897 - 574 стор.
...TABLE OF CAPACITY OF WIRES : ffia. BROWN & SHARPS WIRB GUAGB 'B. & SWG) WIRING RULES AND REQUIREMENTS. and not upon the amount of current to be used on the circuit. Below is a table showing the safe-carrying capacity of conductors of different sizes in Brown & Sharpe gauge, which must be followed...
Повний перегляд - Докладніше про цю книгу

An Elementary Book on Electricity & Magnetism & Their Applications ...

Dugald Caleb Jackson - 1902 - 568 стор.
...current exceeds a proper value. 341. Safe Carrying Capacity of Wires. — In general, the size of a fuse depends upon the size of the smallest conductor...protects, and not upon the amount of current to be used in the circuit. Below is a table showing the safe carrying capacity of copper conductors of different...