| American Institute of Electrical Engineers - 1897 - 710 стор.
...(Fusts and Circuit Breakers.) (See A\TO. 17, and for construction, Nos. 44. and 43.) a. Must be placed on all service wires, either overhead or underground,...arranged to cut off the entire current from the building. Where the switch required by Rule No. 22 is inside the building, the cut-out required by this section... | |
| American Society of Mechanical Engineers - 1898 - 1122 стор.
...comtruetion, No». 44 and 45.) a. Must be placed on all service wires, either overhead or under" ground, as near as possible to the point where they enter the building and inside the walls, and be arranged to cut off the entire current from the building. Where the switch required by Rule No.... | |
| Francis Bacon Crocker - 1901 - 514 стор.
...(Fuses and Circuit-Breakers). (See No. 17, and for construction Nos. 52 and 53.) a. Must be placed on all service wires, either overhead or underground,...arranged to cut off the entire current from the building. Where the switch required by rule No. 22 is inside the building, the cutout required by this section... | |
| Horatio Alvah Foster - 1901 - 1018 стор.
...(Fuses and Circuit-Breakers). (See jVo. 17, and for construction Nos. 52 and 53.) a. Must be placed on all service wires, either overhead or underground,...building and inside the walls, and arranged to cut oil the entire current from the building. "Where the switch required by rule No. 22 is inside the building,... | |
| Francis Bacon Crocker - 1901 - 528 стор.
...each of all service wires as near as possible to the point where they enter the building, on inside of the walls, and arranged to cut off the entire current from the building. The wires then run to the service switch, which should be capable of opening the circuit when carrying... | |
| Francis Bacon Crocker - 1901 - 528 стор.
...Automatic cut-outs such as circuit breakers or fuses should be placed on each of all service wires as near as possible to the point where they enter the building, on inside of the walls, and arranged to cut off the entire current from the building. The wires then... | |
| 1902 - 750 стор.
...Junction boxes are used in electric wiring work to protect and hold cut-outs. Cut-outs must be placed on all service wires, either overhead or underground,...arranged to cut off the entire current from the building. They must be placed at every point wnere a change is made in the size of wire (unless the cut-out in... | |
| 1902 - 738 стор.
...box or mounted on porcelain knobs. Automatic Cut-Outs (Fuses and Circuit-Breakers) a. Must be placed on all service wires, either overhead or underground,...arranged to cut off the entire current from the building. Where the required switch is inside the building, the cutout required by this section must be placed... | |
| Harry Cooke Cushing - 1902 - 204 стор.
...conducting pipe. Automatic Cut-Outs such as circuit breakers and fuses should be placed on all service wires as near as possible to the point where they enter the building, on the inside of the walls, and arranged to cut off the entire current from the building. The cut-out... | |
| Francis Cruger Moore - 1903 - 890 стор.
...3. Suitable switches,* arranged to cut off the entire current, must be placed on all service wires as near as possible to the point where they enter the building; particularly on arc currents where they should be located outside in a non-combustible case easily... | |
| |