" ... the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed as to be subject to mechanical... "
Electric Wiring Specifications for Incandescent Lighting - Сторінка 47
автори: George H. Kimber - 1896 - 59 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...conductor or two separate conductors, in a single tube, unless the said two separate conductors or twin conductor, having an approved insulation, are enclosed...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...subject to mechanical injury by saws, chisels, or nails. («) Must not be supplied with a twin conductor or two separate conductors, in a single tube, unless...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...conductor, or two separate conductors, in a single tube. f. Must have all ends closed with good adhesive material, either at junction boxes or elsewhere, whether...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete...subject to mechanical injury by saws, chisels or nails. (. Must not be supplied with a twin conductor or two separate conductors in a single tube, except in...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...conductor, or two separate conductors in a single tube. (See foregoing note.) / Must have all ends closed with good adhesive map terial, either at junction-boxes...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...conductor, or two separate conductors, in a single tube. (See Rule 22.) f. Must have all ends closed with good adhesive material, either at junction boxes or...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...Must not be supplied with a twin conductor, or two aeparate conductors, in a single tube. (See Rule 22.) f. Must have all ends closed with good adhesive...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...possible, completed. d. Must not be so placed as to to be subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...possible, completed. d. Must not be so placed as to to be subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...40^). The use of concentric wire (see No. 40 fl is recommended in preference to twin conductors. a Must not be drawn in until all mechanical work on...building has been, as far as possible, completed. /. Must not have wires of different circuits drawn in the same conduit. q. Must, for alternating systems,...
Повний перегляд - Докладніше про цю книгу