" Must each be heavily insulated with a coating of moisture-proof material from the point of entrance to the transformer, and, in addition, must be so covered and protected that mechanical injury to them, or contact with them, shall be practically impossible.... "
Electric Wiring Specifications for Incandescent Lighting - Сторінка 55
автори: George H. Kimber - 1896 - 59 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...Between these points the conductors must be heavily insulated with a coating of moisture-proof material, and, in addition, must be so covered and protected...contact with them shall be practically impossible. 3. The primary conductors, if within a building, must be furnifhed with a double-pole switch, and also...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...Between these points the conductors must be heavily insulated with a coating of moisture-proof material, and, in addition, must be so covered and protected...contact with them shall be practically impossible. 3. The primary conductors, if within a building, must be furnished with a double pole switch, and also...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...Between these points the conductors must be heavily insulated with a coating of moisture-proof material, and, in addition, must be so covered and protected...contact with them shall be practically impossible. 3. The primary conductors, if within a building, must be furnished with a double pole switch, and also...
Повний перегляд - Докладніше про цю книгу

A Hand-book of Wiring Tables for Arc, Incandescent Lighting, and Motor Circuits

Arthur Eugene Watson - 1892 - 118 стор.
...heavily insulated with a coating of approved waterproof material, and, in addition, must be so covered-in and- protected, that mechanical injury to them, or...contact with them, shall be practically impossible. 34. These primary conductors, if within a building, must also be furnished with a double-pole switch,...
Повний перегляд - Докладніше про цю книгу

Transformers: Their Theory, Construction and Amplification Simplified

Caryl Davis Haskins - 1892 - 168 стор.
...heavily insulated with a coating of approved waterproof material and, in addition, must be so covered-in and protected that mechanical injury to them, or contact with them, shall be practically impossible. These primary conductors, if within a building, must also be furnished with a double-pole switch, or...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...within a building, must be furnished \vith a double pole switch, and also with an automatic double pole cut-out where the wires enter the building, or where they leave the main line, on the pole or in the conduit. These switches should, if possible, be inclosed in secure and fireproof...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...that it shall be thoroughly ventilated to the outdoor air, if possible, through a chimney or flue. 34. PRIMARY CONDUCTORS— a. Must each be heavily insulated...enter the building, or where they leave the main line, on the pole or in the conduit. These switches should be enclosed in secure and fireproof boxes preferably...
Повний перегляд - Докладніше про цю книгу

Practical Dynamo Building: With Detail Drawings and Instructions for Winding

La Motte C. Atwood - 1893 - 180 стор.
...insulated with a coating of approved water-proof material, and, in addition, must be so covered in and protected that mechanical injury to them, or contact with them, shall be practically impossible. 34. These primary conductors, if within a building, must also be furnished with a double-pole switch,...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...Between them points the conductors must be heavily Insulated with a coating of moisture-proof material, and In addition must be so covered and protected that...contact with them shall be practically impossible. 3. The primary conductors, if within a building, must be furnished with a double pole switch, and also...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...conductors, if within a building, must be furnished with a double-pole switch, and also with a double-pole cut-out where the wires enter the building, or where they leave the main line on the pole or in the conduit. These switches should, if possible, be inclosed in secure and fireproof...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub