" Supply conductors, and especially the splices to fixture wires, must be kept clear of the grounded part of gas pipes, and where shells are used, the latter must be constructed in a manner affording sufficient area to allow this requirement. "
Electric Wiring Specifications for Incandescent Lighting - Сторінка 51
автори: George H. Kimber - 1896 - 59 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...110 95 85 75 65 60 50 40 8 10 18 14 16 18 80 35 30 80 15 10 5 8 25 20 12 8 5 3 3.. 85 30 20 15 10 5 3 must be kept clear of the grounded part of gas pipes,...affording sufficient area to allow this requirement. (e) When fixtures are wired outside, the conductors must be so secured as not to be cut or abraded...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...variation in temperature. Insulating joints with soft rubber in their construction will not be approved. b. Supply conductors, and especially the splices to...wires, must be kept clear of the grounded part of gas-pipes, and where shells are used the latter must be constructed in a manner affording sufficient...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...sufficiently strong to resist the strain they will be liable to in attachment.] b. Supply-conductors and especially the splices to fixture wires, must be kept clear of the grounded part of gas-pipes, and where shells are used the latter must be constructed in a manner affording sufficient...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...approved rubber insulating covering (see No. 40 <i), and shall not be less in size than No. 18, B * s. v. Supply conductors, and especially the splices to fixture...in a manner affording sufficient area to allow this reqxiirement. tu. Must, when fixtures are wired outside, be so secured as not to be cut or abraded...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...approved rubber insulating covering (see No. 40 (f), and shall not be less in size than No. 18 B. & S. v. Supply conductors, and especially the splices to fixture...affording sufficient area to allow this requirement. iff. Must, when fixtures are wired outside, be so secured as not to be cut or abraded by the pressure...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 528 стор.
...and especially the splices to fixture wires, must be kept clear of the grounded part of gas-pipes; and. where shells are used, the latter must be constructed...affording sufficient area to allow this requirement. 11. Must, when fixtures are wired outside, be so secured as not to be cut or abraded by the pressure...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...and especially the Fplices to fixtures wires, must be kept clear of the grounded part of gas-pipes ; and, where shells are used, the latter must be constructed...affording sufficient area to allow this requirement. r. Must, when fixtures are wired outside, be so secured as not to be cut or abraded by the pressure...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for ..., Том 13

1902 - 738 стор.
...after 3 minutes' electrification with 550 volts. b. Must not be less in size than No. 18 B. & S. c. Supply conductors, and especially the splices to fixture...affording sufficient area to allow this requirement. d. Must, when fixtures are wired outside, be so secured as not to be cut or abraded by the pressure...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...No. 16 for mechanical reasons. Supply conductors, and especially the splices to fixture wires, should be kept clear of the grounded part of gas pipes, and where shells are used the latter should have area enough to prevent pressing the wires against the gas pipe when finally in place. Where...
Повний перегляд - Докладніше про цю книгу

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - 1903 - 320 стор.
...16, for mechanical reasons. Supply conductors, and especially the splices to fixture wires, should be kept clear of the grounded part of gas pipes, and where shells are used the latter should have area enough to prevent pressing the wires against the gas pipe when finally in place. Where...
Повний перегляд - Докладніше про цю книгу