" ... e. Must be kept free from contact with gas, water or other metallic piping, or any other conductors or conducting material which they may cross, by some continuous and firmly fixed non-conductor, creating a separation of at least one inch. "
Electric Wiring Specifications for Incandescent Lighting - Сторінка 43
автори: George H. Kimber - 1896 - 59 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...not liable to be exposed to dampness, by approved insulating bushings specially made for the purpose. (c) Must be kept free from contact with gas, water,...conductors or conducting material which they may cross (except high potential conductors), by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...not liable to be exposed to dampness, by approved insulating bushings specially made for the purpose. (c) Must be kept free from contact with gas, water,...metallic piping, or any other conductors or conducting matt-rial which they may cross (except high potential conductors), by some continuous and firmly fixed...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...approved insulating bushings specially made for the purpose. c. Must be kept free from contact wilh gas, water, or other metallic piping, or any other...conductors or conducting material which they may cross (except high potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...not liable to be exposed to dampness by approved insulating bushings specially made for the purpose. c. Must be kept free from contact with gas, water,...conductors or conducting material which they may cross (except high potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...such as glass or porcelain. dampness by approved insulating bushings specially made for the purpose. c. Must be kept free from contact with gas, water,...conductors or conducting material which they may cross (except high potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...exposed to dampness by afproved insulating bushings specially made for the purpose. (See Definitions.) c. Must be kept free from contact with gas, water...conductors or conducting material which they may cross (except high potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...the usual lengths of tube made for conduit work, nor when made without a head or flange on one end.] c. Must be kept free from contact with gas, water,...conductors or conducting material which they may cross (except high-potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...the purpose. (See Definitions,) Fro. 171. WIRE GDAGB ,'B. W, 9.) NATIONAL BOARD FIRE UNDERWRITERS. c. Must be kept free from contact with gas, water...conductors or conducting material which they may cross (except high potential conductors) by some continuous and firmly fixed non-conductor creating a separation...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...pushed in at each end so as to keep the wire absolutely out of contact with the conducting pipe. e. Must be kept free from contact with gas, water or other metallic pipings, or any other conductors or conducting material which they may cross, by some continuous and...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...pushed in at each end so as to keep the wire absolutely out of contact with the conducting pipe. e. Must be kept free from contact with gas, water, or...rule may sometimes be allowed by special permission. /. Must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...
Повний перегляд - Докладніше про цю книгу