Mechanical Drawing for Plumbers: A Concise, Comprehensive and Practical Treatise on the Subject of Mechanical Drawing, in Its Various Modern Applications to the Work of All who are in Any Way Connected with the Plumbing TradeNorman W. Henley Publishing Company, 1910 - 111 стор. |
З цієї книги
Результати 1-5 із 15
Сторінка 15
... waste , and back air for the lavatory are shown plain , which is inconsistent with the appearance of the fixture itself . The back air pipe running straight up from the crown of the pipe looks as if it must break through the bowl and ...
... waste , and back air for the lavatory are shown plain , which is inconsistent with the appearance of the fixture itself . The back air pipe running straight up from the crown of the pipe looks as if it must break through the bowl and ...
Сторінка 18
... Waste Stack Wall Drip Board Fig . 17 - Showing How Curves are Put In , Joining Lines at Odd Angles line , and from this point , with a distance on the compasses equal to that from will join both lines as the upper sketch in Fig . 16 ...
... Waste Stack Wall Drip Board Fig . 17 - Showing How Curves are Put In , Joining Lines at Odd Angles line , and from this point , with a distance on the compasses equal to that from will join both lines as the upper sketch in Fig . 16 ...
Сторінка 19
... waste and vent lines , leaving the plumber to put in his connections according to his Own ideas . However , on many of the best jobs nowadays , architects are giving an eleva- tion , showing the manner in which the work is to be laid ...
... waste and vent lines , leaving the plumber to put in his connections according to his Own ideas . However , on many of the best jobs nowadays , architects are giving an eleva- tion , showing the manner in which the work is to be laid ...
Сторінка 20
... waste and vent lines would have come one in front of the other instead of side by side as the front elevation shows , and the trap and its back air pipe would not have shown broadside to us , as Fig . 19 represents . Therefore , in this ...
... waste and vent lines would have come one in front of the other instead of side by side as the front elevation shows , and the trap and its back air pipe would not have shown broadside to us , as Fig . 19 represents . Therefore , in this ...
Сторінка 21
... waste would have to run , it would be the means of his giving more attention to the location Rain Leader Rain Leader Bath Room Stack Wash Trays Fresh Cit Inlet main Trap Scale 1⁄4 - inch to 1 foot . of his fixtures , the laying out of ...
... waste would have to run , it would be the means of his giving more attention to the location Rain Leader Rain Leader Bath Room Stack Wash Trays Fresh Cit Inlet main Trap Scale 1⁄4 - inch to 1 foot . of his fixtures , the laying out of ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor A. A. HOUGHTON Air Brake Alternating Current angle Architect's Scales back air Bed Room boiler branch cellar plan Cellar Wall CHAPTER COMPOUND LOCOMOTIVES connection construction contains COTTAGE HOUSE curves drawn dynamos edition Electric eleva figure fittings fixtures floor plans Fresh Air Inlet front elevation fully illustrated gas engine give given globe valve horizontal hubs inch Kitchen Stack Lavatory lines of pipe Locomotive machine machinist main drain main line main stack main trap main vent matter mechanical drawing method milling cutters modern molds motors O'CONOR SLOANE pantry sink perspective plain plumber plumbing drawings practical treatise Price readers refrigerator represents roof second floor shading shown in Fig Side View space STARBUCK Steam Engine straight lines tee square threads tion toilet room triangle valuable Valve Gear vent line Walschaert Valve Gear Wash Trays water closet wrought iron