Mechanical Drawing for Plumbers: A Concise, Comprehensive and Practical Treatise on the Subject of Mechanical Drawing, in Its Various Modern Applications to the Work of All who are in Any Way Connected with the Plumbing TradeNorman W. Henley Publishing Company, 1910 - 111 стор. |
З цієї книги
Результати 1-5 із 13
Сторінка 21
... foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc .. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting , etc. , than he is usually ...
... foot . of his fixtures , the laying out of bath rooms , the running of floor timbers , etc .. and as a result , the plumber would find himself able to put in his work to better advantage , with less cutting , etc. , than he is usually ...
Сторінка 22
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
Сторінка 23
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
Сторінка 74
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
Сторінка 76
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 76 MECHANICAL DRAWING FOR PLUMBERS.
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 76 MECHANICAL DRAWING FOR PLUMBERS.
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor A. A. HOUGHTON Air Brake Alternating Current angle Architect's Scales back air Bed Room boiler branch cellar plan Cellar Wall CHAPTER COMPOUND LOCOMOTIVES connection construction contains COTTAGE HOUSE curves drawn dynamos edition Electric eleva figure fittings fixtures floor plans Fresh Air Inlet front elevation fully illustrated gas engine give given globe valve horizontal hubs inch Kitchen Stack Lavatory lines of pipe Locomotive machine machinist main drain main line main stack main trap main vent matter mechanical drawing method milling cutters modern molds motors O'CONOR SLOANE pantry sink perspective plain plumber plumbing drawings practical treatise Price readers refrigerator represents roof second floor shading shown in Fig Side View space STARBUCK Steam Engine straight lines tee square threads tion toilet room triangle valuable Valve Gear vent line Walschaert Valve Gear Wash Trays water closet wrought iron