Automobile Starting, Lighting and Ignition: Elementary Principles, Practical Application, Wiring Diagrams and Repair Hints; a Complete Exposition Explaining All Forms of Electrical Ignition Systems Used with Internal Combustion Engines of All Types, Also Includes a Comprehensive Series of Instructions Pertaining to Starting and Lighting Systems of Automobiles; Describes Storage Battery Construction and Maintenance, Magneto Timing, Care of Motors and Generators and Systematic Location of All Electrical Faults; Invaluable to Motorists, Students, Mechanics and Repair Men, Every Phase of the Subject is Treated in an Easily Understood, Non-technical Manner |
З цієї книги
Результати 1-5 із 100
Сторінка 27
The points to be watched out for when installing dry batteries are clearly outlined
at the bottom of Fig . 4 . It will be seen that it is not desirable for terminals to come
in contact with each other or with the sides of the box or is it conducive to good ...
The points to be watched out for when installing dry batteries are clearly outlined
at the bottom of Fig . 4 . It will be seen that it is not desirable for terminals to come
in contact with each other or with the sides of the box or is it conducive to good ...
Сторінка 44
000000 Ball Bearing Armature Primary Winding Condenser Platinum Tipped
Screw gap which exists between the points of the conventional spark. Ball
Bearing Distributor Shaft Distributor Segment21 High Tension Brush WW2 fety
Spark ...
000000 Ball Bearing Armature Primary Winding Condenser Platinum Tipped
Screw gap which exists between the points of the conventional spark. Ball
Bearing Distributor Shaft Distributor Segment21 High Tension Brush WW2 fety
Spark ...
Сторінка 45
gap which exists between the points of the conventional spark plug , a separate
coil is placed in circuit to intensify the current to ... At the point of greatest potential
in the armature winding the current is broken by the contact breaker , which is ...
gap which exists between the points of the conventional spark plug , a separate
coil is placed in circuit to intensify the current to ... At the point of greatest potential
in the armature winding the current is broken by the contact breaker , which is ...
Сторінка 47
During the revolution of the armature the grounded lever makes and breaks
contact with the insulated point , short ... feeble currents will pass through the
primary winding , and so long as the contact points are together this condition will
exist .
During the revolution of the armature the grounded lever makes and breaks
contact with the insulated point , short ... feeble currents will pass through the
primary winding , and so long as the contact points are together this condition will
exist .
Сторінка 48
When the current reaches its maximum value , because of the armature being in
the best position , the cam operates the interrupter and the points are separated ,
breaking the short circuit which has existed in the primary winding .
When the current reaches its maximum value , because of the armature being in
the best position , the cam operates the interrupter and the points are separated ,
breaking the short circuit which has existed in the primary winding .
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
adjusted amperes armature attached automatic bearings breaker brush Bulb button cable carried cause cells centre charging closed clutch coil commutator complete condition connection construction cover crank cylinder D.U. Willard Delco device Diagram direction discharge distributor driving dynamo electrical engine field flow flywheel frame fuse gear Gray & Davis ground hand HEAD LIGHT ignition indicated insulating lamp lead lever lighting Lighting System located machine magneto means mechanical metal method mounted necessary operation pass piece pinion plate points pole position primary produced proper reduction regulator relay removed resistance running screw secondary segments separate shaft short circuit Showing shown at Fig shunt side simple spark plug speed spring starting motor starting switch storage battery terminal timer trouble turn unit usually vibrator voltage volts Westinghouse winding wire