Automobile Starting, Lighting and Ignition: Elementary Principles, Practical Application, Wiring Diagrams and Repair Hints; a Complete Exposition Explaining All Forms of Electrical Ignition Systems Used with Internal Combustion Engines of All Types, Also Includes a Comprehensive Series of Instructions Pertaining to Starting and Lighting Systems of Automobiles; Describes Storage Battery Construction and Maintenance, Magneto Timing, Care of Motors and Generators and Systematic Location of All Electrical Faults; Invaluable to Motorists, Students, Mechanics and Repair Men, Every Phase of the Subject is Treated in an Easily Understood, Non-technical Manner |
З цієї книги
Результати 1-5 із 50
Сторінка 28
5 , A . The storage battery differs from the primary cell in that the elements are
composed of the same metal before charging takes place , usually lead instead
of being zinc or carbon . One of the plates is termed the “ positive ” and may be ...
5 , A . The storage battery differs from the primary cell in that the elements are
composed of the same metal before charging takes place , usually lead instead
of being zinc or carbon . One of the plates is termed the “ positive ” and may be ...
Сторінка 29
After the charging process is complete the lead plates have become so changed
in nature that they may be considered as different substances and a chemical
action results between the negative plate and the electrolyte and produces
current ...
After the charging process is complete the lead plates have become so changed
in nature that they may be considered as different substances and a chemical
action results between the negative plate and the electrolyte and produces
current ...
Сторінка 30
New electrolyte or distilled water can be easily inserted through holes in which
the vents are screwed . The cells of which a storage battery is composed are
joined together at the factory with bars of lead which are burned in place and only
two ...
New electrolyte or distilled water can be easily inserted through holes in which
the vents are screwed . The cells of which a storage battery is composed are
joined together at the factory with bars of lead which are burned in place and only
two ...
Сторінка 61
III MASO Scalem Scale Pointer Permanent Magnet Fixed Soft Iron Core Pivot
Moving Coil Soft Iron Coil Return Spring Scale Plunger ULI Solenoid Coil
AAAAAAAAA AAAAAAAAA Scale Flexible Lead Pivoty Contact Point C
Counterbalance ...
III MASO Scalem Scale Pointer Permanent Magnet Fixed Soft Iron Core Pivot
Moving Coil Soft Iron Coil Return Spring Scale Plunger ULI Solenoid Coil
AAAAAAAAA AAAAAAAAA Scale Flexible Lead Pivoty Contact Point C
Counterbalance ...
Сторінка 71
The condenser is shunted in between the vibrator points , i . e . , one of the leads
is attached to terminal No . 1 while the other is soldered to the end of the primary
coil which goes on the vibrator spring member . One end of the secondary coil is
...
The condenser is shunted in between the vibrator points , i . e . , one of the leads
is attached to terminal No . 1 while the other is soldered to the end of the primary
coil which goes on the vibrator spring member . One end of the secondary coil is
...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
adjusted amperes armature attached automatic bearings breaker brush Bulb button cable carried cause cells centre charging closed clutch coil commutator complete condition connection construction cover crank cylinder D.U. Willard Delco device Diagram direction discharge distributor driving dynamo electrical engine field flow flywheel frame fuse gear Gray & Davis ground hand HEAD LIGHT ignition indicated insulating lamp lead lever lighting Lighting System located machine magneto means mechanical metal method mounted necessary operation pass piece pinion plate points pole position primary produced proper reduction regulator relay removed resistance running screw secondary segments separate shaft short circuit Showing shown at Fig shunt side simple spark plug speed spring starting motor starting switch storage battery terminal timer trouble turn unit usually vibrator voltage volts Westinghouse winding wire