Automobile Starting, Lighting and Ignition: Elementary Principles, Practical Application, Wiring Diagrams and Repair Hints; a Complete Exposition Explaining All Forms of Electrical Ignition Systems Used with Internal Combustion Engines of All Types, Also Includes a Comprehensive Series of Instructions Pertaining to Starting and Lighting Systems of Automobiles; Describes Storage Battery Construction and Maintenance, Magneto Timing, Care of Motors and Generators and Systematic Location of All Electrical Faults; Invaluable to Motorists, Students, Mechanics and Repair Men, Every Phase of the Subject is Treated in an Easily Understood, Non-technical Manner |
З цієї книги
Результати 1-5 із 54
Сторінка 18
The overcharged body always tends to discharge to the undercharged body in
order to equalize a difference in pressure existing between them . An electrical
machine capable of producing current may distribute this current as desired ...
The overcharged body always tends to discharge to the undercharged body in
order to equalize a difference in pressure existing between them . An electrical
machine capable of producing current may distribute this current as desired ...
Сторінка 21
element K to the negative element L , until the pressures on both are equal ,
when the current will stop flowing and the cell will be discharged . If a valve C is
placed in the pipe , connecting the two tanks , the flow of the water may be
stopped .
element K to the negative element L , until the pressures on both are equal ,
when the current will stop flowing and the cell will be discharged . If a valve C is
placed in the pipe , connecting the two tanks , the flow of the water may be
stopped .
Сторінка 28
Some voltaic couples are reversible , i . e . , they may be recharged when they
have become exhausted by passing a current of electricity through them in a
direction opposite to that in which the current flows on discharge . Such batteries
are ...
Some voltaic couples are reversible , i . e . , they may be recharged when they
have become exhausted by passing a current of electricity through them in a
direction opposite to that in which the current flows on discharge . Such batteries
are ...
Сторінка 30
When the plates are discharged they are regenerated by passing a current of
electricity through them . New electrolyte or distilled water can be easily inserted
through holes in which the vents are screwed . The cells of which a storage
battery ...
When the plates are discharged they are regenerated by passing a current of
electricity through them . New electrolyte or distilled water can be easily inserted
through holes in which the vents are screwed . The cells of which a storage
battery ...
Сторінка 31
When chemical current producers are depended upon to supply the electricity
used for ignition , two distinct sets are provided , Expansion Chamber to take care
of Changes in Volume of Solution during Charge and Discharge . Hard Rubber ...
When chemical current producers are depended upon to supply the electricity
used for ignition , two distinct sets are provided , Expansion Chamber to take care
of Changes in Volume of Solution during Charge and Discharge . Hard Rubber ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
adjusted amperes armature attached automatic bearings breaker brush Bulb button cable carried cause cells centre charging closed clutch coil commutator complete condition connection construction cover crank cylinder D.U. Willard Delco device Diagram direction discharge distributor driving dynamo electrical engine field flow flywheel frame fuse gear Gray & Davis ground hand HEAD LIGHT ignition indicated insulating lamp lead lever lighting Lighting System located machine magneto means mechanical metal method mounted necessary operation pass piece pinion plate points pole position primary produced proper reduction regulator relay removed resistance running screw secondary segments separate shaft short circuit Showing shown at Fig shunt side simple spark plug speed spring starting motor starting switch storage battery terminal timer trouble turn unit usually vibrator voltage volts Westinghouse winding wire