Automobile Starting, Lighting and Ignition, Elementary Principles, Practical Application, Wiring Diagrams and Repair Hints ...N.W. Henley Publishing Company, 1917 - 519 стор. |
З цієї книги
Результати 1-5 із 59
Сторінка 36
... removed , having a north and south pole and all of the properties found in the energizing magnet . This is magnetizing by contact . A piece of steel will retain the magnetism imparted to it for a considerable length of time , and the ...
... removed , having a north and south pole and all of the properties found in the energizing magnet . This is magnetizing by contact . A piece of steel will retain the magnetism imparted to it for a considerable length of time , and the ...
Сторінка 37
... removal from the source of magnetism is known as a permanent magnet . If a piece of iron or steel is brought into the magnetic field of a powerful magnet it becomes a magnet without actual contact with the energizer . This is ...
... removal from the source of magnetism is known as a permanent magnet . If a piece of iron or steel is brought into the magnetic field of a powerful magnet it becomes a magnet without actual contact with the energizer . This is ...
Сторінка 38
... removed from between the pole pieces there would exist a field of magnetic influence as shown at Fig . 7 , but the introduction of this component provides a con- ductor ( the iron core ) for the magnetic energy 38 Starting , Lighting ...
... removed from between the pole pieces there would exist a field of magnetic influence as shown at Fig . 7 , but the introduction of this component provides a con- ductor ( the iron core ) for the magnetic energy 38 Starting , Lighting ...
Сторінка 74
... removed from the box without disturbing any internal connection , and a new one slipped in its place if it does not function properly . Special care is taken in insulating the high- tension terminal by means of rubber caps which ...
... removed from the box without disturbing any internal connection , and a new one slipped in its place if it does not function properly . Special care is taken in insulating the high- tension terminal by means of rubber caps which ...
Сторінка 97
... removed , or with the ignition resistance unit shorted out , or with a defective condenser , these contacts burn rapidly and in a short time will cause serious ignition trouble . The car should not be oper- ated with the battery removed ...
... removed , or with the ignition resistance unit shorted out , or with a defective condenser , these contacts burn rapidly and in a short time will cause serious ignition trouble . The car should not be oper- ated with the battery removed ...
Інші видання - Показати все
Загальні терміни та фрази
ammeter amount amperemeter amperes armature armature shaft attached Auto-Lite automatic Ball Bearing Battery Ignition System Bijur Bosch brush Bulb G.R. button cable charging circuit breaker clutch commutator conductor connection contact breaker contact points core crank crankshaft cutout cylinder D.U. Willard Delco device discharge distributor dry cells dynamo electrical electrolyte field winding flywheel fuse Gray & Davis ground HEAD LIGHT HORN IGNITION COIL ignition system inch induction coil insulating lamp lever fully LIGHTING SWITCH Lighting System magneto mechanism metal method motor-generator operation pinion plates plunger pole pieces position produced regulator relay Remy resistance revolving rotation running S.U. Exide screw secondary winding segments short circuit Showing shown at Fig shunt field side spark plug speed spring starter Starting and Lighting starting motor starting switch storage battery terminal timer tion top dead centre transformer coil trouble tube turn unit vibrator voltage volts W'house Westinghouse wiring diagram