Сховані поля
Книги Книги
" The switch must be so constructed that it shall be automatic in its action, not stopping between points when started, and prevent an arc between the points under all circumstances ; it must indicate on inspection whether the current be " on " or  "
Electrical Engineer - Сторінка 200
1894
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...doublecontact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...moisture and easy of access to police or firemen. 3. Always in plain sight, never covered, except in special cases, where an armoured tube may be necessary....
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...contact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...moisture, and easy of access to police or firemen. 3. Always in plain sight, never covered, except in special cases, where an armored tube may be necessary....
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...double contact switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...moisture, and easy -of access to police or firemen. 3. Always in plain sight, never covered, except in special cases, where an armored tube may be necessary....
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...contact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...whether the current be "on" or "off," and be mounted in a lion-combustible case, and kept free from moisture and easy of access to police or firemen. (c)...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...indicate on inspection whether the current be "on" or "off," and be mounted in a non-combustible case, and kept free from moisture and easy of access to police or firemen. (c) Must be always in plain sight, and never encased, except when required by the inspector. (d) Must...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...contact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...whether the current be "on" or "off," and be mounted in a non.combustible case, and kept free from moisture and easy of access to police or firemen. c....
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...contact service switch, which will effectually close the main circuit, and disconnect the interior wires when it is turned " off." The switch must be so constructed...moisture and easy of access to police or firemen. 3. Must be always in plain sight, never covered, except in special cases, where an armored tube may...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...contact service-switch, which will effectually close the main circuit and disconnect the interior wires when it is turned " off." The switch must be so constructed...whether the current be " on " or " off," and be mounted in a non-combustible case, and kept free from moisture, and easy of access to police or firemen. So-called...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...contact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...whether the current be " on " or " off," and be mounted in a noncombustible case, and kept free from moisture, and easy of access to police or firemen. So-called...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 стор.
...contact service switch, which will effectually close the main circuit and disconnect the interior wires when it is turned "off." The switch must be so constructed...whether the current be " on " or " off," and be mounted in a noncombustible case, and kept free from moisture, and easy of access to police or firemen. So-called...