" No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts... "
Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps, Steam ... - Сторінка 327
1906
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...No. 2 ESG (e) All burrs or fins must be removed before the conductors are drawn into a fixture. (/) The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. (g) No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...or No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into a fixture. /. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
..., No. 2 ESG e. All burs or fins must be removed before the conductors are drawn into a fixture. /. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...smaller than No. 18 B. & S., No. 20 BWG, No. 2 ESG before the conductors are drawn into a fixture. /. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 стор.
...BWG, No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into a fixture. /. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...BWG, No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into a fixture. / The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...BWG, No. 2 ESG e. All burrs or fins must be removed before the conductors are drawn into a fixture. f. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture g. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...ceiling. b. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. "if. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...ceiling. t>. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...celling. b. Must have all burs, or fins, removed before the conductois are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...