" The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed as to be subject to mechanical injury by saws, chisels or nails. "
The National Electrical Code: An Analysis and Explanation of the ... - Сторінка 212
автори: Richard Henry Pierce - 1896 - 222 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...conductor or two separate conductors, in a single tube, unless the said two separate conductors or twin conductor, having an approved insulation, are enclosed...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...subject to mechanical injury by saws, chisels, or nails. (e) Must not be supplied with a twin conductor or two separate conductors, in a single tube, unless...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin conductor, or two separate conductors, in a single tube. f. Must...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...subject to mechanical injury by saws, chisels or nails. e. Must not be supplied with a twin conductor, or two separate conductors, in a single tube. (See Rule...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin conductor, or two separate conductors in a single tube. (See foregoing...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...possible, completed. d. Must not be so placed as to to be subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been,...possible, completed. d. Must not be so placed as to to be subject to mechanical injury by saws, chisels, or nails. e. Must not be supplied with a twin...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...and the conductors then to be pushed or fished in. The conductors triust not be placed in position until all mechanical work on the building has been, as far as possible, completed. * Architects are advised to make out detailed distribution sheets, similar to the one on page 38, showing...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...40^). The use of concentric wire (see No. 40 fl is recommended in preference to twin conductors. a Must not be drawn in until all mechanical work on...building has been, as far as possible, completed. /. Must not have wires of different circuits drawn in the same conduit. q. Must, for alternating systems,...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...e). The use of concentric wire (see No. 40 c) is recommended in preference to twin conductors. • o. Must not be drawn in until all mechanical work on...building has been, as far as possible, completed. p. Must not have wires of different circuits drawn in the same conduit. </. Must, for alternating systems,...