Electric Wiring for the Use of Architects, Underwriters, and the Owners of BuildingsMacmillan and Company, 1896 - 183 стор. |
З цієї книги
Результати 1-5 із 7
Сторінка 10
... trical pressure , corresponding to " pounds per square inch " in hydraulics , is called the " volt , " and the elec- tro - motive force is often spoken of as the " voltage . " The unit of current , corresponding to " gallons per minute ...
... trical pressure , corresponding to " pounds per square inch " in hydraulics , is called the " volt , " and the elec- tro - motive force is often spoken of as the " voltage . " The unit of current , corresponding to " gallons per minute ...
Сторінка 32
... trical energy and the more familiar mechanical energy . Seven When an electric circuit is broken , energy is no longer being expended , for although the electrical pressure may be kept constant , the current , the other factor ...
... trical energy and the more familiar mechanical energy . Seven When an electric circuit is broken , energy is no longer being expended , for although the electrical pressure may be kept constant , the current , the other factor ...
Сторінка 52
... trical system ; and it makes this system of wires capable of change or renewal at any time . But with any method the electrical features should have consideration when the building is designed . This does not make necessary any great ...
... trical system ; and it makes this system of wires capable of change or renewal at any time . But with any method the electrical features should have consideration when the building is designed . This does not make necessary any great ...
Сторінка 81
... trical connection , or cross - connection , between the two wires . In a similar way , if the two wires in Figure 27 were fastened to the front of a building , and the upper wire were to become loose and to hang near the lower , water G ...
... trical connection , or cross - connection , between the two wires . In a similar way , if the two wires in Figure 27 were fastened to the front of a building , and the upper wire were to become loose and to hang near the lower , water G ...
Сторінка 156
... trical transformer there is no electrical connection between the two coils ; there is a space between them , and the current in the primary coil with its high- pressure is not free to pass to the secondary coil . In practice the ...
... trical transformer there is no electrical connection between the two coils ; there is a space between them , and the current in the primary coil with its high- pressure is not free to pass to the secondary coil . In practice the ...
Інші видання - Показати все
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... Russell Robb Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
air-space alternating currents ampères approved arc lamp attached batteries become break building burn by-path carbons carrying capacity cause combustible material concealed conductors conduit connection construction copper copper wire cross-connection cuit current passes damp danger devices double-pole ductors dynamo earth elec electric circuit electrical pressure electro-motive force energy excessive current exposed fastened fire fixture floor flow fuse fusible cut-out gas-pipe glass or porcelain globe ground hanger-board heat high-potential incandescent lamps inch inflammable inflammable material Inigo Jones installed insulating covering Insulating-joints leak leakage liable light lightning-arrester low-potential mains melt metal moisture motor multiple system multiple-series necessary neutral wire Ohm's law operated path pipe placed possible potential prevent protected resistance-box rheostat Rule 18 Section series circuit service-switch short circuit shown in Figure socket soldered space switch switch-board temperature tion transformer trical tube underwriters volts W. J. LOFTIE walls waterproof wires leading
Популярні уривки
Сторінка 127 - Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller).
Сторінка 140 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts...
Сторінка 64 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 121 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 112 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 123 - Must not be of such material or construction that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 162 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule also applies to feeders.
Сторінка 112 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 139 - Must be entirely made of material that will resist the action of illuminating gases and will not give way or soften under the heat of an ordinary gas flame or leak under a moderate pressure.