Electric Wiring for the Use of Architects, Underwriters, and the Owners of BuildingsMacmillan and Company, 1896 - 183 стор. |
З цієї книги
Результати 1-5 із 82
Сторінка 6
... electric insula- tors can be either punctured or permeated by con- ductors ... circuit . And it is by no means the waste only that makes leaks undesirable ... electric circuits are in successful operation . If a few principles are kept in ...
... electric insula- tors can be either punctured or permeated by con- ductors ... circuit . And it is by no means the waste only that makes leaks undesirable ... electric circuits are in successful operation . If a few principles are kept in ...
Сторінка 10
... electric circuit , from the actions that take place , from the visible manifesta- tions of the electrical energy . By continued experience one gradually gets an idea of the relative resistance of conductors of different sizes and ...
... electric circuit , from the actions that take place , from the visible manifesta- tions of the electrical energy . By continued experience one gradually gets an idea of the relative resistance of conductors of different sizes and ...
Сторінка 15
... electric circuit is what determines the total heat generated by a given current , it is the amount of resistance per foot that , with a given cur- rent , determines the temperature to which the wire will be raised . On the other hand ...
... electric circuit is what determines the total heat generated by a given current , it is the amount of resistance per foot that , with a given cur- rent , determines the temperature to which the wire will be raised . On the other hand ...
Сторінка 21
... electric cir- It is of course E cuits takes the simple form ( C = ( c = 1 ) . R necessary to know only two of these quantities to de- termine the third . Suppose there is to be a current of ten ampères in a circuit that is known to have ...
... electric cir- It is of course E cuits takes the simple form ( C = ( c = 1 ) . R necessary to know only two of these quantities to de- termine the third . Suppose there is to be a current of ten ampères in a circuit that is known to have ...
Сторінка 22
... Electric Circuits . Suppose that at C , 500 feet away , there is a cluster of 20 lamps , each requiring one - half ampère to make it burn at the proper candle - power . Then there should be a total of 10 ampères flowing in the circuit ...
... Electric Circuits . Suppose that at C , 500 feet away , there is a cluster of 20 lamps , each requiring one - half ampère to make it burn at the proper candle - power . Then there should be a total of 10 ampères flowing in the circuit ...
Інші видання - Показати все
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... Russell Robb Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
air-space alternating currents ampères approved arc lamp attached batteries become break building burn by-path carbons carrying capacity cause combustible material concealed conductors conduit connection construction copper copper wire cross-connection cuit current passes damp danger devices double-pole ductors dynamo earth elec electric circuit electrical pressure electro-motive force energy excessive current exposed fastened fire fixture floor flow fuse fusible cut-out gas-pipe glass or porcelain globe ground hanger-board heat high-potential incandescent lamps inch inflammable inflammable material Inigo Jones installed insulating covering Insulating-joints leak leakage liable light lightning-arrester low-potential mains melt metal moisture motor multiple system multiple-series necessary neutral wire Ohm's law operated path pipe placed possible potential prevent protected resistance-box rheostat Rule 18 Section series circuit service-switch short circuit shown in Figure socket soldered space switch switch-board temperature tion transformer trical tube underwriters volts W. J. LOFTIE walls waterproof wires leading
Популярні уривки
Сторінка 127 - Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller).
Сторінка 140 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts...
Сторінка 64 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 121 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 112 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 123 - Must not be of such material or construction that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 162 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule also applies to feeders.
Сторінка 112 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 139 - Must be entirely made of material that will resist the action of illuminating gases and will not give way or soften under the heat of an ordinary gas flame or leak under a moderate pressure.