Electric Wiring for the Use of Architects, Underwriters, and the Owners of BuildingsMacmillan and Company, 1896 - 183 стор. |
З цієї книги
Результати 1-5 із 15
Сторінка 49
... conduit , to be supported wholly on non - com- bustible insulators . It is their intention that wires shall not even come in contact with anything else . They also have made stringent regulations with re- gard to the insulation that is ...
... conduit , to be supported wholly on non - com- bustible insulators . It is their intention that wires shall not even come in contact with anything else . They also have made stringent regulations with re- gard to the insulation that is ...
Сторінка 52
... conduit is in- stalled at the time the building is erected , the actual wiring may be left until all carpenters and finishers have gone , and when there is no longer danger from carelessly driven nails or slashing tools . The space ...
... conduit is in- stalled at the time the building is erected , the actual wiring may be left until all carpenters and finishers have gone , and when there is no longer danger from carelessly driven nails or slashing tools . The space ...
Сторінка 106
... conduit and con- nected therewith by specially insulated conductors , kept apart not less than two and one - half inches . [ Section b . The cut - out required by this section must be placed so as to protect the switch . ] c . Must not ...
... conduit and con- nected therewith by specially insulated conductors , kept apart not less than two and one - half inches . [ Section b . The cut - out required by this section must be placed so as to protect the switch . ] c . Must not ...
Сторінка 109
... approved insulating covering , and must not be of sizes smaller than No. 14 B. & S. , No. 16 B. W. G. , or No. 4 E. S. G. , except that in conduit installed under Rule 22 , No. 16 B. & S. , No. THE NATIONAL CODE OF RULES . - CLASS C. 109.
... approved insulating covering , and must not be of sizes smaller than No. 14 B. & S. , No. 16 B. W. G. , or No. 4 E. S. G. , except that in conduit installed under Rule 22 , No. 16 B. & S. , No. THE NATIONAL CODE OF RULES . - CLASS C. 109.
Сторінка 114
... Conduit : a . Must be supported wholly on non - combustible insula tors , constructed so as to prevent the insulating coverings of the wire from coming in contact with other substances than the insulating supports . b . Must be so ...
... Conduit : a . Must be supported wholly on non - combustible insula tors , constructed so as to prevent the insulating coverings of the wire from coming in contact with other substances than the insulating supports . b . Must be so ...
Інші видання - Показати все
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... Russell Robb Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
air-space alternating currents ampères approved arc lamp attached batteries become break building burn by-path carbons carrying capacity cause combustible material concealed conductors conduit connection construction copper copper wire cross-connection cuit current passes damp danger devices double-pole ductors dynamo earth elec electric circuit electrical pressure electro-motive force energy excessive current exposed fastened fire fixture floor flow fuse fusible cut-out gas-pipe glass or porcelain globe ground hanger-board heat high-potential incandescent lamps inch inflammable inflammable material Inigo Jones installed insulating covering Insulating-joints leak leakage liable light lightning-arrester low-potential mains melt metal moisture motor multiple system multiple-series necessary neutral wire Ohm's law operated path pipe placed possible potential prevent protected resistance-box rheostat Rule 18 Section series circuit service-switch short circuit shown in Figure socket soldered space switch switch-board temperature tion transformer trical tube underwriters volts W. J. LOFTIE walls waterproof wires leading
Популярні уривки
Сторінка 127 - Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller).
Сторінка 140 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts...
Сторінка 64 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 121 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 112 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 123 - Must not be of such material or construction that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 162 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule also applies to feeders.
Сторінка 112 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 139 - Must be entirely made of material that will resist the action of illuminating gases and will not give way or soften under the heat of an ordinary gas flame or leak under a moderate pressure.