Molten antimonious lead is then poured in to fill the spaces between the tablets ,
and to insure a proper flow of metal it is forced into the mould under
approximately 75 pounds pressure . Upon cooling , the result is a solid lead grid ,
in which ...
Molten antimonious lead is then poured in to fill the spaces between the tablets ,
and to insure a proper flow of metal it is forced into the mould under
approximately 75 pounds pressure . Upon cooling , the result is a solid lead grid ,
in which ...
Сторінка 42
The initial rating is conservative , however , so that if a battery is given a proper
initial charge it will give its rated discharge at the start . This will gradually
increase in use , so that the output becomes greater , and then there is a
dropping off ...
The initial rating is conservative , however , so that if a battery is given a proper
initial charge it will give its rated discharge at the start . This will gradually
increase in use , so that the output becomes greater , and then there is a
dropping off ...
Сторінка 54
... only water of the proper purity used for replacing evaporation . - Holes Burnt
through Separator Charred Ribs B Cracked Jar А Grid Spaces Denuded of Active
Material Crystalized Active Material Crystalized Active Material C -Sulphate Fig .
... only water of the proper purity used for replacing evaporation . - Holes Burnt
through Separator Charred Ribs B Cracked Jar А Grid Spaces Denuded of Active
Material Crystalized Active Material Crystalized Active Material C -Sulphate Fig .
Сторінка 55
The proper time to take a reading of a storage battery is immediately upon
stopping or while the engine is running . A more definite determination can be
made than after the battery has been idle for a few hours and has recuperated
more or ...
The proper time to take a reading of a storage battery is immediately upon
stopping or while the engine is running . A more definite determination can be
made than after the battery has been idle for a few hours and has recuperated
more or ...
Сторінка 56
The plates may be sulphated , due to lack of proper charge or too long discharge
. The cells may need cleaning , a condition indicated by short capacity and a
tendency to overheat when charging . Sometimes a deposit of sediment on the ...
The plates may be sulphated , due to lack of proper charge or too long discharge
. The cells may need cleaning , a condition indicated by short capacity and a
tendency to overheat when charging . Sometimes a deposit of sediment on the ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Storage Batteries Simplified, Operating Principles--care and Industrial ... Victor Wilfred Pagé Перегляд фрагмента - 1917 |
Загальні терміни та фрази
acid action active material amperes automobile capacity cell cents charge chart chemical circuit complete compound Concrete condition connected consists construction contains cover described detail device direction discharge drawing dynamo Edison edition electric electrolyte elements engine field flow fully Gear given gives heating ignition illustrated inches installation iron lamps lead lighting Locomotive machine magnet means mechanical metal method motor necessary needed negative obtained operation pass plants plates positive posts pounds practical Price produced proper readings remove repair resistance result rubber sealing separators shown shows side simple space specific gravity speed starting steam steel storage battery supply switch tank terminal tion trouble unit usually Valve various voltage wire wood zinc