Storage Batteries Simplified, Operating Principles--care and Industrial Applications: A Complete, Non-technical But Authoritative Treatise Discussing the Development of the Modern Storage Battery, Outlining the Basic Operation of the Leading Types |
З цієї книги
Результати 1-5 із 38
Сторінка 53
... as possible without slighting any essential points . In view of the general
adoption of motor starting and lighting systems on all modern automobiles , the
repairman or motorist must pay more attention to the electrical apparatus than
formerly ...
... as possible without slighting any essential points . In view of the general
adoption of motor starting and lighting systems on all modern automobiles , the
repairman or motorist must pay more attention to the electrical apparatus than
formerly ...
Сторінка 90
Clean with ammonia or washing soda ; cout with vaseline . Excessive gassing :
Metal battery box corroded . Use lower charging rate - coat Poor box ventilation .
box interior with asphaltum paint . Battery discharged . Starting motor will not start
...
Clean with ammonia or washing soda ; cout with vaseline . Excessive gassing :
Metal battery box corroded . Use lower charging rate - coat Poor box ventilation .
box interior with asphaltum paint . Battery discharged . Starting motor will not start
...
Сторінка 94
... the amount of current passing through the batteries , which is placed in series
with each battery . If the service is of higher voltage , a motor generator or rotary
converter set . may be used . If alternating current only is available , various types
...
... the amount of current passing through the batteries , which is placed in series
with each battery . If the service is of higher voltage , a motor generator or rotary
converter set . may be used . If alternating current only is available , various types
...
Сторінка 95
Back of Switchboard Back of Switchboard 0 Front of Switchboard R. O 4 5 R.
Field Terminals Motor Generator Motor Generator field - coil rheostat is shown at
Fig . 37. Vm . O R. & L. Rheostat Rheostat Connect Nos . 1 & 2 to Battery Nos.6 &
7 ...
Back of Switchboard Back of Switchboard 0 Front of Switchboard R. O 4 5 R.
Field Terminals Motor Generator Motor Generator field - coil rheostat is shown at
Fig . 37. Vm . O R. & L. Rheostat Rheostat Connect Nos . 1 & 2 to Battery Nos.6 &
7 ...
Сторінка 98
Dynamo , 1 Motor Vibrator Rectifier Main Circuit Leads 1 MUN 1 --- Plug for Lamp
Socket Charging Lead's Battery B A Fig . 41. — Devices for Rectifying Alternating
Current . A— Vibrator Type Rectifier . B - Small Rotary Converter Set ...
Dynamo , 1 Motor Vibrator Rectifier Main Circuit Leads 1 MUN 1 --- Plug for Lamp
Socket Charging Lead's Battery B A Fig . 41. — Devices for Rectifying Alternating
Current . A— Vibrator Type Rectifier . B - Small Rotary Converter Set ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Storage Batteries Simplified, Operating Principles--care and Industrial ... Victor Wilfred Pagé Перегляд фрагмента - 1917 |
Загальні терміни та фрази
acid action active material amperes automobile capacity cell cents charge chart chemical circuit complete compound Concrete condition connected consists construction contains cover described detail device direction discharge drawing dynamo Edison edition electric electrolyte elements engine field flow fully Gear given gives heating ignition illustrated inches installation iron lamps lead lighting Locomotive machine magnet means mechanical metal method motor necessary needed negative obtained operation pass plants plates positive posts pounds practical Price produced proper readings remove repair resistance result rubber sealing separators shown shows side simple space specific gravity speed starting steam steel storage battery supply switch tank terminal tion trouble unit usually Valve various voltage wire wood zinc