Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 1-5 із 17
Сторінка 5
... Usually Drawn by the Architect . Cellar and Floor Plans . CHAPTER V. The Drawing of Soil Pipe Hubs , Binds , Fittings and Traps . CHAPTER VI . The Making of Complete Elevations of Plumbing Systems . CHAPTER VII . Practice Drawings for ...
... Usually Drawn by the Architect . Cellar and Floor Plans . CHAPTER V. The Drawing of Soil Pipe Hubs , Binds , Fittings and Traps . CHAPTER VI . The Making of Complete Elevations of Plumbing Systems . CHAPTER VII . Practice Drawings for ...
Сторінка 21
... usually drawn up by the architect having the work in charge , and such , no doubt , as most of our readers are entire- ly familiar with . These views are what the plumber us- ually figures his work from , and as a general thing he has ...
... usually drawn up by the architect having the work in charge , and such , no doubt , as most of our readers are entire- ly familiar with . These views are what the plumber us- ually figures his work from , and as a general thing he has ...
Сторінка 23
... usually . On ordinary work , the scale generally used is 14 inch to the foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the ...
... usually . On ordinary work , the scale generally used is 14 inch to the foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the ...
Сторінка 31
... usually show the pipes on the cellar bottom to such good advantage as the cellar plan can . In Fig . 33 we give a front elevation of the plumbing for the house as shown in Fig . 32 , and in Fig . 34 , the side elevation . Fig . 34 ...
... usually show the pipes on the cellar bottom to such good advantage as the cellar plan can . In Fig . 33 we give a front elevation of the plumbing for the house as shown in Fig . 32 , and in Fig . 34 , the side elevation . Fig . 34 ...
Сторінка 38
... usually be better , though in the present instance it does not matter particularly . It will be noticed that in these exer- cises we have shown both sink and lava- tory in two positions , one in which it is seen from the front , and the ...
... usually be better , though in the present instance it does not matter particularly . It will be noticed that in these exer- cises we have shown both sink and lava- tory in two positions , one in which it is seen from the front , and the ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron
Популярні уривки
Сторінка 52 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.