... length of steel rod having six faces . If the piece is placed so that it is squarely in front of the person making the drawing , with a face fully exposed , the front and top views would be such as Fig . 8 shows , but if placed in some ...
... length of steel rod having six faces . If the piece is placed so that it is squarely in front of the person making the drawing , with a face fully exposed , the front and top views would be such as Fig . 8 shows , but if placed in some ...
Сторінка 17
... length of the fitting , and consequently should be laid out with the 45 degree 1 . Incorrect じ Fig . 15 -Another Example of Correct and Incorrect Work intersection of the branch with the main part of the fitting . Do not make it in the ...
... length of the fitting , and consequently should be laid out with the 45 degree 1 . Incorrect じ Fig . 15 -Another Example of Correct and Incorrect Work intersection of the branch with the main part of the fitting . Do not make it in the ...
Сторінка 23
... lengths of pipes a fifty per cent . loss . Now if any of our readers wish to en- large these plans as we have suggested , and draw them on a larger scale , it can easily be done . If it is desired to make the drawings four times the ...
... lengths of pipes a fifty per cent . loss . Now if any of our readers wish to en- large these plans as we have suggested , and draw them on a larger scale , it can easily be done . If it is desired to make the drawings four times the ...
Сторінка 29
... length of the straight lines con- necting the vent hubs with the trap . As seen in No. 1 , these hubs set close to the trap , and are close together . We have taken up the construction of these par- ticular fittings in order that use ...
... length of the straight lines con- necting the vent hubs with the trap . As seen in No. 1 , these hubs set close to the trap , and are close together . We have taken up the construction of these par- ticular fittings in order that use ...
Сторінка 37
... length , and erase whatever runs by , after putting in the curves . Now , in laying out these drawings , if they are to be made on a special scale , of course it will be neces- sary to work according to such scale , FIG . 40 Fig . 40 ...
... length , and erase whatever runs by , after putting in the curves . Now , in laying out these drawings , if they are to be made on a special scale , of course it will be neces- sary to work according to such scale , FIG . 40 Fig . 40 ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron