Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 1-5 із 12
Сторінка 21
... foot . as are usually drawn up by the architect having the work in charge , and such , no doubt , as most of our readers are entire- ly familiar with . These views are what the plumber us- ually figures his work from , and as a general ...
... foot . as are usually drawn up by the architect having the work in charge , and such , no doubt , as most of our readers are entire- ly familiar with . These views are what the plumber us- ually figures his work from , and as a general ...
Сторінка 22
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
... foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends will appear circular . Now when we come to study the ...
Сторінка 23
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
... foot . On large work inch to the foot is common . This brings to mind the fact that in working or figuring from plans care must be taken to do such work with the scale that the drawings are made on . The writer has heard several times ...
Сторінка 74
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
... Foot of Kitchen Stack Cleanout room stack , on the two floor plans , shows that it must be offset on the first floor , to get around the dividing wall . While it is impossible on the drawing itself to show that a double T Y is used for ...
Сторінка 76
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 76 MECHANICAL DRAWING FOR PLUMBERS.
... simply shows that wherever detail drawings are given they should be given full attention . Concerning Fig . 86 , all there is to be said is that this foot connection cannot be shown on 76 MECHANICAL DRAWING FOR PLUMBERS.
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron
Популярні уривки
Сторінка 52 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.