Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing Work |
З цієї книги
Результати 1-5 із 20
Сторінка 15
... branch of drawing , the two views must never be run together , as they must
have been to give the view of the water closet shown in Fig . 10 . Another point to
be observed in connection with the work shown in Fig . 10 is that , if the drawing
is ...
... branch of drawing , the two views must never be run together , as they must
have been to give the view of the water closet shown in Fig . 10 . Another point to
be observed in connection with the work shown in Fig . 10 is that , if the drawing
is ...
Сторінка 17
14 , notic and not inked , as that will be taken up that the branch is at 45 degrees
with thi later on . Since no inking is to be done , length of the fitting , and
consequentl ; all lines should be made plain and not should be laid out with the
45 degre ...
14 , notic and not inked , as that will be taken up that the branch is at 45 degrees
with thi later on . Since no inking is to be done , length of the fitting , and
consequentl ; all lines should be made plain and not should be laid out with the
45 degre ...
Сторінка 26
A regular Y branch is always Noi . NO2 . FIG . 28 . The Main Pipe Drawn With a
Tee Square - Lines of Branch With 45 Degree Triangle . the horizontal , and can
be obtained sim - at an angle of 45 deg . with the main line ply by drawing a line ...
A regular Y branch is always Noi . NO2 . FIG . 28 . The Main Pipe Drawn With a
Tee Square - Lines of Branch With 45 Degree Triangle . the horizontal , and can
be obtained sim - at an angle of 45 deg . with the main line ply by drawing a line ...
Сторінка 27
Many times the eighth bend will be used between a Y branch and a straight run
of pipe . In this case , draw in the lines for the Y branch and the straight line , then
connect these lines with the proper curve . Not until this is done should the hub ...
Many times the eighth bend will be used between a Y branch and a straight run
of pipe . In this case , draw in the lines for the Y branch and the straight line , then
connect these lines with the proper curve . Not until this is done should the hub ...
Сторінка 33
35 , shows a T - Y . The branch is actually a short one and not carried on a wide
sweep , with the branch , but so far out as No . 2 shows . The depth of hubs
should be about twothirds the diameter of the pipe . The vented T - Y is shown in
its ...
35 , shows a T - Y . The branch is actually a short one and not carried on a wide
sweep , with the branch , but so far out as No . 2 shows . The depth of hubs
should be about twothirds the diameter of the pipe . The vented T - Y is shown in
its ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
able advantage angle appear arrow back air bath Bath Room believe better branch building carried cellar plan CHAPTER clear clearly common connection consider course curves desired difficult direction distance dotted double drain drainage drawing drawn elevation entirely exercises fact figure fittings fixtures floor plans foot front give given horizontal hubs illustrations inch instance Kitchen larger latter Lavatory laying lead length light lines lines of pipe looking manner method necessary noticed object obtained parallel perspective piece pipe plain plumber plumbing position practice preceding present readers reason refrigerator represents residence roof Room scale seen shading shown in Fig side simply sink sketch space square stack straight lines student taken thing tion trap triangle usually vent vertical wall waste
Популярні уривки
Сторінка 110 - CORROSIONj by FJ Rowan. GAS FITTING AND LIGHTING, by William Paul Gerhard. HOUSE DRAINAGE AND SANITARY PLUMBING, by WP Gerhard. HYDRAULIC TABLES, by PJ Flynn. RECENT PRACTICE IN SANITARY DRAINAGE OF BLDGS. Wm. Paul Gerhard. SANITARY CONDITION OF DWELLING HOUSES, by George E. Waring. SEWER GASES, NATURE AND ORIGIN, by De Varona. SEWERAGE AND SEWAGE PURIFICATION, by MN Baker, Ph.B. THE TREATMENT OF SEWAGE, by Dr. C. M. Tidy. THE DISPOSAL OF HOUSEHOLD WASTE, by W. Paul Gerhard. WATER AND WATER SUPPLY,...
Сторінка 110 - EXTERNAL PLUMBING WORK, by John W. Hart 3.00 HEATING AND VENTILATING BUILDINGS, by Carpenter 4.00 HEATING AND VENTILATION. Tables and Formulas. By F. Schumann I-'" HISTORY OF SANITATION, by JJ Cosgrove 1.50 HOT WATER SUPPLY, by F.
Сторінка 110 - E. Waring. Sewer Gases, Nature and Origin, by De Varona. Sewerage and Sewage Purification, by MN Baker, Ph.B. The Treatment of Sewage, by Dr. CM Tidy. The Disposal of Household Waste, by W. Paul Gerhard. Water and Water Supply, by WH Corfield. These books are for sale by The Plumbers...
Сторінка 50 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.
Сторінка 110 - Colyer 1.50 Modern Methods of Sewage Disposal, by Geo. E. Waring, Jr 2.00 Modern Plumbing, by RM Starbuck, charts 3.00 Plumbing and House Drainage Problems 2.00 Plumbers' Text Book, 300 questions and answers, by Frank Tower....
Сторінка 110 - Questions and Answers on the Practice and Theory of Steam and Hot Water Heating, by RM Starbuck...
Сторінка 110 - American Sanitary Plumbing (revised second edition), for plumbers 2.00 lawler's Hot Water Heating, Steam and Gas Pitting 2.00 Iiawler's Modern Plumbing 5.0O Iiead Burning by the Autogenious Process 1.00 Mechanics' Companion, by JM Scribner 1.50 Modern Sanitary Appliances, by Colyer 1.50 Modern Methods of Sewage Disposal, by Geo.
Сторінка 110 - External Plumbing Work, by John W. Hart 3.00 Heating and Ventilating Buildings, by Carpenter 4.00 Heating and Ventilation. Tables and Formulas. By F. Schumann 1.50 Hot Water Circulation Charts, by RM Starbuck 3.00 Hot Water Supply, by F.