Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 1-5 із 16
Сторінка 15
... lavatory is shown entirely in perspective , and the water closet partly so . The latter shows especially poor taste . A glance at the water closet will show that while the main part of the bowl is shown plain , the circular rim is shown ...
... lavatory is shown entirely in perspective , and the water closet partly so . The latter shows especially poor taste . A glance at the water closet will show that while the main part of the bowl is shown plain , the circular rim is shown ...
Сторінка 30
... Lavatory 1 st . Floor Lavatory -Sink Wash Trays °° D 2nd Floor Attic Cellar 1st Floor 22 . Bath Room Elev- ation . such as are ordinarily submitted by the architect and an 30 CHAPTER VI CHAPTER VI The Making of Complete Elevations of ...
... Lavatory 1 st . Floor Lavatory -Sink Wash Trays °° D 2nd Floor Attic Cellar 1st Floor 22 . Bath Room Elev- ation . such as are ordinarily submitted by the architect and an 30 CHAPTER VI CHAPTER VI The Making of Complete Elevations of ...
Сторінка 32
... lavatory shown on the first floor plan to be at the right of -No 3 . No1 . No 2 . No 4 . FIG.35 . Correct and Incorrect Drawing for Fittings . of the house from the front would give . We wish to make ourselves very clear on this point ...
... lavatory shown on the first floor plan to be at the right of -No 3 . No1 . No 2 . No 4 . FIG.35 . Correct and Incorrect Drawing for Fittings . of the house from the front would give . We wish to make ourselves very clear on this point ...
Сторінка 33
... lavatory just referred to shows that it is set away and from the stack in a certain manner , this we cannot show nearly so well in the elevation . The latter view shows how high the fixture is set , etc. , which the plan cannot show ...
... lavatory just referred to shows that it is set away and from the stack in a certain manner , this we cannot show nearly so well in the elevation . The latter view shows how high the fixture is set , etc. , which the plan cannot show ...
Сторінка 38
... lavatory appears to set too close to the ceiling , and that the vertical lines of pipe are broken . It often happens that in order to economize space , fixtures shown in illustrations appear too close to the ceiling . Many times this is ...
... lavatory appears to set too close to the ceiling , and that the vertical lines of pipe are broken . It often happens that in order to economize space , fixtures shown in illustrations appear too close to the ceiling . Many times this is ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron