" to the passage of an unvarying electrical current, when the coil of insulated wire forming part of the aforesaid instrument and connected to the aforesaid terminals is in all parts at a temperature of 15°'4 C. "
Electric Lighting and Power Distribution: An Elementary Manual on Electrical ... - Сторінка 189
автори: William Perren Maycock - 1896
Повний перегляд - Докладніше про цю книгу

Notices of the Proceedings at the Meetings of the Members of the ..., Том 14

Royal Institution of Great Britain - 1896 - 758 стор.
...in the recent Order iu Council regarding Standards for Electrical Measurements is as follows : — " A standard of electrical resistance denominated one...insulated wire forming part of the aforesaid instrument aiid connected to the aforesaid terminals is in all parts at a temperature of 15 • 4° C." This is...
Повний перегляд - Докладніше про цю книгу

Statutory Rules and Orders Other Than Those of a Local, Personal Or ...

Great Britain - 1894 - 610 стор.
...denominations of standards for electrical measurement. 0. L. Fed. SCHEDULE. I. — STANDARD OF ELECTRICAL RESISTANCE. A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 15 • 4 C. II. — STANDARD OF ELECTRICAL CURRENT. A standard of electrical current denominated...
Повний перегляд - Докладніше про цю книгу

Report of the Annual Meeting

British Association for the Advancement of Science - 1894 - 1204 стор.
...denominations of standards for electrical measurement. CL PEKL. SCHEDULE. I. — Standard of Electrical Resistance. A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 15c-4 C. II. Standard of Electrical Current. A standard of electrical current denominated one ampere...
Повний перегляд - Докладніше про цю книгу

Report of the ... Meeting of the British Association for the ..., Том 64

British Association for the Advancement of Science - 1894 - 1104 стор.
...denominations of standards for electrical measurement. CL PEEL. SCHEDULE. I. — Standard of Electrical Resistance. A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 15°-4 C. II. Standard of Electrical Current. A standard of electrical current denominated one ampere...
Повний перегляд - Докладніше про цю книгу

Notices of the Proceedings, Том 14

Royal Institution of Great Britain - 1896 - 740 стор.
...in the recent Order in Council regarding Standards for Electrical Measurements is as follows : — " A standard of electrical resistance denominated one...aforesaid terminals is in all parts at a temperature of 15 -4° C." This is a plain adoption of an arbitrary standard. The resistance of a certain piece...
Повний перегляд - Докладніше про цю книгу

Practical Electricity: A Laboratory and Lecture Course for First Year ..., Том 1

William Edward Ayrton - 1897 - 688 стор.
...new denominations of Standards for electrical measurement. CLP SCHEDULE. I.— STANDARD OF ELECTRICAL RESISTANCE. A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 154°C. II.— STANDARD OF ELECTRICAL CURRENT. exerted by gravity in Westminster upon the iridioplatinum...
Повний перегляд - Докладніше про цю книгу

Elementary Lessons in Electricity & Magnetism

Silvanus Phillips Thompson - 1902 - 650 стор.
...as new denominations of standards for electrical measurement. SCHEDULE I.—STANDARD OF ELECTRICAL RESISTANCE A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 15'4° C. II.—STANDARD OF ELECTRICAL CURRENT A standard of electrical current denominated one...
Повний перегляд - Докладніше про цю книгу

Electric Lighting and Power Distribution: An Elementary Manual of ..., Том 1

William Perren Maycock - 1902 - 486 стор.
...Board of Trade offices. Following are their official definitions : — (a) STANDARD OP RBSISTANCB. " A standard of electrical resistance denominated one...aforesaid terminals is in all parts at a temperature of 15-4C." (&) STANDARD OP CURRENT. " A standard of electrical current denominated one amper being...
Повний перегляд - Докладніше про цю книгу

Sanitary Engineering: A Practical Manual of Town Drainage & Sewage & Refuse ...

Francis Wood - 1902 - 400 стор.
...standard ohm is the resistance between the copper terminals of the Board of Trade standard instrument to the passage of an unvarying electrical current, when the coil of wire between the terminals is at the uniform temperature of 15 - 4° C. The ampere is the measure of...
Повний перегляд - Докладніше про цю книгу

The Law Relating to Electric Lighting, Traction and Power

John Shiress Will - 1903 - 570 стор.
...denominations of standards for electrical measurement. Order in SCHEDULE. Council I. — STANDARD OF ELECTRICAL RESISTANCE. A standard of electrical resistance denominated...aforesaid terminals is in all parts at a temperature of 15'4 C. II. — STANDABD OF ELECTRICAL CURRENT. A standard of electrical current denominated one...