Electric Lighting Specifications for the Use of Engineers and ArchitectsW. J. Johnston Company, 1896 - 213 стор. |
З цієї книги
Результати 1-5 із 14
Сторінка xii
... terminate in secondary junc- tion boxes ) · Taps • 112 · 113 Junction Boxes Cut - outs 113 114 Fuses 114 Switches 114 Fixture Supports 114 Sizes of Tubes 114 Fastenings Joints Elbow Limitation Outlets Floor Work with Brass or xii CONTENTS .
... terminate in secondary junc- tion boxes ) · Taps • 112 · 113 Junction Boxes Cut - outs 113 114 Fuses 114 Switches 114 Fixture Supports 114 Sizes of Tubes 114 Fastenings Joints Elbow Limitation Outlets Floor Work with Brass or xii CONTENTS .
Сторінка 28
... . Number . Vertical . Horizontal . Kind . Return tubular . Boilers ? Water tube . Horse - power . Fittings . Setting . Tools . Renewal parts . Stack ? Material . Diameter . Height . Flues and 28 ELECTRIC LIGHTING SPECIFICATIONS .
... . Number . Vertical . Horizontal . Kind . Return tubular . Boilers ? Water tube . Horse - power . Fittings . Setting . Tools . Renewal parts . Stack ? Material . Diameter . Height . Flues and 28 ELECTRIC LIGHTING SPECIFICATIONS .
Сторінка 110
... tubes are installed all open- ings in walls and floors shall be sealed so that it shall be impossible , in the event of fire , for smoke or flame to pass from one floor to another or from one room to an- other about the tubes . ( See p ...
... tubes are installed all open- ings in walls and floors shall be sealed so that it shall be impossible , in the event of fire , for smoke or flame to pass from one floor to another or from one room to an- other about the tubes . ( See p ...
Сторінка 113
... tube may be employed provided the current required does not exceed { amperes . risers The terminals of all the feeders mains and taps shall be brought together in junction boxes at the points designated in this specification and on the ...
... tube may be employed provided the current required does not exceed { amperes . risers The terminals of all the feeders mains and taps shall be brought together in junction boxes at the points designated in this specification and on the ...
Сторінка 114
... tubes shall be of sufficient size to allow the wires to be readily drawn in , withdrawn and reinserted at will . Tubes , whether concealed or on the surface , should be held in place by the fastenings especially designed for use with ...
... tubes shall be of sufficient size to allow the wires to be readily drawn in , withdrawn and reinserted at will . Tubes , whether concealed or on the surface , should be held in place by the fastenings especially designed for use with ...
Інші видання - Показати все
Загальні терміни та фрази
Alternating Current ampere meter apparatus and material approved arc lamps Architects armature attached automatic baseframe bidder shall fill bids binding posts candle-power capacity carried ceiling cleats conductors conduit contractor shall furnish cuits cut-outs and switches Direct Current distribution circuits double-pole dynamos Trade number Electric erect the follow fill out completely fixtures floor foundation foundation(s full load ground detector H. P. required hand regulator hanger boards Incandescent incombustible bases installation insulated junction boxes justment kilowatts knife switch least C. M. less than ohms lightning arresters load for consecutive lugs or set main wires manner affecting namo Number of lights number or designation operating dynamos outlets pipe placed pole potential pressure proper pulley at full purchaser Rating of exciters ratus riser feeder Riser Group securely fastened set screw Sockets soldered Spark arresters specifications spirit and intent suitable device sulated taps tests Three-Wire tightened tion tube voltage voltmeter volts
Популярні уривки
Сторінка 211 - Should the Contractor be obstructed or delayed in the prosecution or completion of his work by the act, neglect, delay or default of the Owner, or the Architects, or of any other contractor...
Сторінка 170 - Underground Conductors. a. Must be protected against moisture and mechanical injury where brought into a building, and all combustible material must be kept from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch-box.
Сторінка 173 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 183 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing will be approved. e. Must be tested for "contacts" between conductors and fixtures, for "short circuits" and for ground connections before it is connected to its supply conductors.
Сторінка 211 - ... of the Contractor, then the time herein fixed for the completion of the work shall be extended for a period equivalent to the time lost by reason of any or all of the causes aforesaid ; but no such allowance shall be made unless a claim therefor is presented in writing to the Architects within twenty-four hours of the occurrence of such delay.
Сторінка 207 - No alterations shall be made in the work shown or described by the drawings and specifications, except upon a written order of the Architect...
Сторінка 194 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 213 - If at any time there shall be evidence of any lien or claim for which, if established, the Owner of the said premises might become liable, and which is chargeable to the Contractor , the Owner shall have the right to retain out of any payment then due or thereafter to become due an amount sufficient to completely indemnify against such lien or claim.
Сторінка 212 - ART. ix. It is hereby mutually agreed between the parties hereto that the sum to be paid by the Owner to the Contractor for said work and materials shall be $ , subject to additions and deductions as hereinbefore provided, and that such sum shall be paid in current funds by the Owner to the Contractor in installments, as follows: The final payment shall be made within days after this contract is fulfilled.
Сторінка 199 - The insulating covering of the wire to be approved under this section must be solid, at least 3 -64th of an inch in thickness, and covered with a substantial braid. It must not readily carry fire, must show an insulating resistance of one megohm per mile after two weeks...