Electric Wiring for the Use of Architects, Underwriters, and the Owners of BuildingsMacmillan and Company, 1896 - 183 стор. |
З цієї книги
Результати 1-5 із 12
Сторінка 13
... lead it is very plain that the energy is transformed into heat . Meteors falling through the atmosphere are heated to incandescence , and even when water is forced through a pipe , a part 13 of the energy is transformed into heat ...
... lead it is very plain that the energy is transformed into heat . Meteors falling through the atmosphere are heated to incandescence , and even when water is forced through a pipe , a part 13 of the energy is transformed into heat ...
Сторінка 22
... proper candle - power . Then there should be a total of 10 ampères flowing in the circuit . If the lamps were at A , attached directly to the leads from the dynamo , they would of course have the benefit 22 ELECTRIC WIRING .
... proper candle - power . Then there should be a total of 10 ampères flowing in the circuit . If the lamps were at A , attached directly to the leads from the dynamo , they would of course have the benefit 22 ELECTRIC WIRING .
Сторінка 35
... leads are taken off and connected to the lamp . The series system is also satisfactory for incan- descent lights in the streets , but it is unsuited for incandescent lamps for interior lighting . With lamps in all sorts of places as ...
... leads are taken off and connected to the lamp . The series system is also satisfactory for incan- descent lights in the streets , but it is unsuited for incandescent lamps for interior lighting . With lamps in all sorts of places as ...
Сторінка 39
... lead from its terminals , and any branches that are taken from these wires are simply extensions of the mains , proportioned to the current they will have to carry . With a water or gas system , the free space out- side , the air , may ...
... lead from its terminals , and any branches that are taken from these wires are simply extensions of the mains , proportioned to the current they will have to carry . With a water or gas system , the free space out- side , the air , may ...
Сторінка 51
... lead from the mains to the branches , and from the branches to the lamps , and wherever a wire is to be connected to another wire , a " junction - box " is provided . The wires are then drawn through these tubes and the necessary ...
... lead from the mains to the branches , and from the branches to the lamps , and wherever a wire is to be connected to another wire , a " junction - box " is provided . The wires are then drawn through these tubes and the necessary ...
Інші видання - Показати все
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... Russell Robb Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
air-space alternating currents ampères approved arc lamp arc-light attached batteries become break building burn by-path carbons carrying capacity cause combustible material concealed conductors conduit connection construction copper wire cross-connection cuit current passes damp danger devices double-pole ductors dynamo earth elec electric circuit electrical pressure electro-motive force energy excessive current exposed fastened fire fixture floor flow fuse fusible cut-out gas-pipe glass or porcelain globe ground hanger-board heat high-potential incandescent lamps inch inflammable inflammable material Inigo Jones installed insulating covering Insulating-joints leak leakage liability light lightning-arrester low-potential mains melt metal moisture motor multiple system multiple-series necessary neutral wire Ohm's law operated path pipe placed possible potential prevent protected resistance-box rheostat Rule 18 Section series circuit service-switch short circuit shown in Figure socket soldered space switch switch-board temperature tion transformer trical tube underwriters volts W. J. LOFTIE walls waterproof wires leading
Популярні уривки
Сторінка 127 - Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller).
Сторінка 140 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts...
Сторінка 64 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 121 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 135 - ... capacity of the wire is exceeded. 25. TABLE OF CAPACITY OF WIRES:— It must be clearly understood that the size of the fuse depends upon the size of the smallest conductor it protects, and not upon the amount of current to be used on the circuit. Below is a table showing the...
Сторінка 87 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 123 - Must not be of such material or construction that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 162 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule also applies to feeders.
Сторінка 139 - Must be entirely made of material that will resist the action of illuminating gases and will not give way or soften under the heat of an ordinary gas flame or leak under a moderate pressure.
Сторінка 114 - ... b. Must be so arranged that wires of opposite polarity, with a difference of potential of 150 volts or less, will be kept apart at least two and one-half inches, c. Must have the above distance increased proportionately where a higher voltage is used. d. Must not be laid in plaster, cement or similar finish, e. Must never be fastened with staples. IN UNFINISHED LOFTS, BETWEEN FLOORS AND CEILINGS, IN PARTITIONS AND OTHER CONCEALED PLACES:—/'.