... entirely , and the current or flow would continue through the by - passage . This passage round the wheel could be made to offer exactly the same resistance that the wheel did , and in that case the pump could keep on developing the ...
... entirely , and the current or flow would continue through the by - passage . This passage round the wheel could be made to offer exactly the same resistance that the wheel did , and in that case the pump could keep on developing the ...
Сторінка 49
... entirely exposed and is in a per- fectly dry place , a somewhat inferior insulation is allowed . It was thought in the early days that wiring would be perfectly safe and satisfactory if it were simply E buried in the plaster , or if it ...
... entirely exposed and is in a per- fectly dry place , a somewhat inferior insulation is allowed . It was thought in the early days that wiring would be perfectly safe and satisfactory if it were simply E buried in the plaster , or if it ...
Сторінка 53
... entirely cover the smallest tubes , but the larger mains require channels in the walls . In many cases , it is advisable to have the larger tubes in channels provided with removable covers , for the largest wires are not drawn in and ...
... entirely cover the smallest tubes , but the larger mains require channels in the walls . In many cases , it is advisable to have the larger tubes in channels provided with removable covers , for the largest wires are not drawn in and ...
Сторінка 64
... entirely on the face . c . Must be kept free from moisture . d . Must be made of non - combustible material , or of hard wood in skeleton form , filled to prevent absorption of moist- ure . e . Bus - bars must be equipped in accordance ...
... entirely on the face . c . Must be kept free from moisture . d . Must be made of non - combustible material , or of hard wood in skeleton form , filled to prevent absorption of moist- ure . e . Bus - bars must be equipped in accordance ...
Сторінка 98
... entirely enclosed by an extension above the globe . Carbons are usually " plated " because copper is a far better conductor than carbon , and a thin layer of copper on the carbon reduces the resistance and so insures a better contact ...
... entirely enclosed by an extension above the globe . Carbons are usually " plated " because copper is a far better conductor than carbon , and a thin layer of copper on the carbon reduces the resistance and so insures a better contact ...
Інші видання - Показати все
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... Russell Robb Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
air-space alternating currents ampères approved arc lamp arc-light attached batteries become break building burn by-path carbons carrying capacity cause combustible material concealed conductors conduit connection construction copper wire cross-connection cuit current passes damp danger devices double-pole ductors dynamo earth elec electric circuit electrical pressure electro-motive force energy excessive current exposed fastened fire fixture floor flow fuse fusible cut-out gas-pipe glass or porcelain globe ground hanger-board heat high-potential incandescent lamps inch inflammable inflammable material Inigo Jones installed insulating covering Insulating-joints leak leakage liability light lightning-arrester low-potential mains melt metal moisture motor multiple system multiple-series necessary neutral wire Ohm's law operated path pipe placed possible potential prevent protected resistance-box rheostat Rule 18 Section series circuit service-switch short circuit shown in Figure socket soldered space switch switch-board temperature tion transformer trical tube underwriters volts W. J. LOFTIE walls waterproof wires leading
Популярні уривки
Сторінка 127 - Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller).
Сторінка 140 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts...
Сторінка 64 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 121 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Сторінка 135 - ... capacity of the wire is exceeded. 25. TABLE OF CAPACITY OF WIRES:— It must be clearly understood that the size of the fuse depends upon the size of the smallest conductor it protects, and not upon the amount of current to be used on the circuit. Below is a table showing the...
Сторінка 87 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 123 - Must not be of such material or construction that the insulation of the conductor will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 162 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule also applies to feeders.
Сторінка 139 - Must be entirely made of material that will resist the action of illuminating gases and will not give way or soften under the heat of an ordinary gas flame or leak under a moderate pressure.
Сторінка 114 - ... b. Must be so arranged that wires of opposite polarity, with a difference of potential of 150 volts or less, will be kept apart at least two and one-half inches, c. Must have the above distance increased proportionately where a higher voltage is used. d. Must not be laid in plaster, cement or similar finish, e. Must never be fastened with staples. IN UNFINISHED LOFTS, BETWEEN FLOORS AND CEILINGS, IN PARTITIONS AND OTHER CONCEALED PLACES:—/'.