" Must be so suspended that the entire weight of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or rosette, in order that the strain may be taken from the joints... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 134
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...So suspended that the entire weight of the socket and lamp will be borne by knots, above the point where the cord comes through the ceiling block or...cord pendants should have openings at least equal to .; in . gas-pipe size. 4. Allowed to sustain nothing heavier than a four-light cluster, and in such...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...So suspended that the entire weight of the socket and lamp will be borne by knots, above the point where the cord comes through the ceiling block or...should have openings at least equal to onequarter inch gas-pipe size. 4. Allowed to sustain nothing heavier than a fourlight cluster, and in such a case special...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or...strain may be taken from the joints and binding screws. (g) Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...knots under the bushing in the socket, and above the point where the cord comes through the ceil,ng block or rosette, in order that the strain may be taken from the joints and binding screws. g. Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...be so suspended that the entire weight of the socket and lamp will be borne by knote above the point where the cord comes through the ceiling block or...order that the strain may be taken from the joints ana binding screws. All sockets used for wire or cord pendants should have openings at least equal...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...be so suspended that the entire weight of the socket and lamp will be borne by knots above the point where the cord comes through the ceiling block or...order that the strain may be taken from the joints and binding-screws. All sockets used for wire or cord pendants should have openings at least equal to one-quarter...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or...strain may be taken from the joints and binding screws. g. Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or...strain may be taken from the joints and binding screws. g. Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or...strain may be taken from the joints and binding screws. g. Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...under the bushing in the socket, and above the point where the cord comes through the ceiling-block or rosette, in order that the strain may be taken from the joints and binding screws. g. Must be equipped with keyless sockets as far as practicable, and be controlled by wall switches....