Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring ; Modern Electric-lighting Devices ; Electric Signs ; Electric HeatingInternational Textbook Company, 1908 - 639 стор. |
Інші видання - Показати все
Storage Batteries, Incandescent Lighting, ARC Lighting, Interior Wiring ... International Correspondence Schools Попередній перегляд недоступний - 2015 |
Storage Batteries, Incandescent Lighting, Arc Lighting, Interior Wiring ... International Correspondence Schools Попередній перегляд недоступний - 2018 |
Storage Batteries; Incandescent Lighting; ARC Lighting; Interior Wiring ... International Correspondence Schools Попередній перегляд недоступний - 2015 |
Загальні терміни та фрази
adjusted allow alternating current alternating-current ammeter amount ampere-hours amperes arc lamps arc-light armature arranged battery booster Brush burn candlepower carbon cells cent charging circular mils clutch connected in series constant constant-current constant-potential copper core curve cut-out direct current direct-current lamp discharge distance distribution drop dynamo efficiency electric electrodes enclosed arc enclosed-arc lamp feeders feet filament fixture flows fuse ground heat hence incandescent lamps inch increase installed insulation large number light load lower machine magnet mains metal method motors necessary Nernst lamp number of lamps open-arc lamp operated ordinary osmium placed plate plug pole porcelain positive pressure primary reactance regulator resistance rheostat screws secondary series coils series lamps short-circuiting shown in Fig shows shunt coil side socket station supplied switch switchboard tantalum temperature terminals three-wire system tion transformer tube upper carbon usually voltage voltmeter volts watt-hours wire
Популярні уривки
Сторінка 3 - The American Institute of Electrical Engineers; The American Society of Mechanical Engineers; The American Society of Civil Engineers; The American Society of Mining and Metallurgical Engineers; and The American Society for Testing Materials.
Сторінка 65 - Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S.
Сторінка 10 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 64 - Insulation Resistance — The wiring in any building must test free from grounds; ie, the complete installation must have an insulation between conductors and between all conductors and the ground (not including attachments, sockets, receptacles, etc.) of not less than the following: Up to 5 amperes 4,000,000 ohms...
Сторінка 12 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 40 - It offers a temptation to carry about lamps that are intended to hang freely in the air, and the cord adjusters wear off the insulation very rapidly. For all portable work, including...
Сторінка 12 - Must be separated from contact with walls, floors, timbers or partitions through which they may pass by non-combustible, non-absorptive, insulating tubes, such as glass or porcelain, except at outlets where approved flexible tubing is required.
Сторінка 34 - Rigid supporting requires under ordinary conditions, where wiring along flat surfaces, supports at least every four and one-half feet. If the wires are liable to be disturbed, the distance between supports should be shortened. In buildings of mill construction, mains of No.
Сторінка 24 - Cut-outs such as circuit breakers and fuses should be placed on all service wires as near as possible to the point where they enter the building, on the inside of the walls, and arranged to cut off the entire current from the building.
Сторінка 13 - Underground conductors must not be so arranged as to shunt the current through a building around any catch-box. c. Where underground service enters building through tubes, the tubes shall be tightly closed at outlets with asphaltum or other nonconductor, to prevent gases from entering the building through such channels. d. No underground service from a subway to a building...