Сховані поля
Книги Книги
" Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors. "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 171
автори: Earle Abbott Merrill - 1896 - 213 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and...secure without solder. They must then be soldered to ensure preservation, and covered with an insulation equal to that on the conductors. The following...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...partitions through which they may pass, by non-combustible insulating tube or hard rubber tube. (g) Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. LAMPS AND OTHER DEVICES. 1 3. Arc Lamps. — In every case : (a) Must be carefully isolated from inflammable...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and...with an insulation equal to that on the conductors. The following formula for soldering fluid is approved : Saturated Solution of Zinc 5 parts. Alcohol...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. (/) Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. f. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...petticoat insulators of glass or porcelain. Porcelain knob«, cleat« and rubber hooks are prohibited. 7. Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. 1 . Adopted at the Washington Convention, March 1, 1894. NOTB.— These Rulea are subject to amendment«...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...points between the high and low tension conductors. e. Must be so placed in wet places that an air-space will be left between conductors and pipes in crossing,...with an insulation equal to that on the conductors. [Section /. All joints must be soldered, even if made with the Mclntyre or any other patent splicing...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...through which (.hey may pass by non, combustible insulating tube. WIRING RULES AND REQUIREMENTS. g. Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. 13. ARC LAMPS— IN EVERY CASE : a. Must be carefully isolated from inflammable material. b. Must be...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...pipes upon which moisture is likely to gather, or which by leaking might cause trouble on a circuit. e. Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. All joints must be soldered, even if made with the Mclntyre or any other patent splicing device. This...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...walls, floors, timbers or partitions through which they may pass, by noncombustible insulating tube. g. Must be so spliced or joined as to be both mechanically...electrically secure without solder. They must then be ELECTRIC WIRING. soldered, to insure preservation, and covered with an insulation equal to that on...