" No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing will be approved. e. Must be tested for "contacts" between conductors and fixtures, for "short circuits" and... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 181
автори: Earle Abbott Merrill - 1896 - 213 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...the conductors arc drawn into a fixture. (f) The tendency to condensation within the pipes should bo guarded against by sealing the upper end of the fixture....inside pipe and the outside casing will be approved. (It) Each fixture must be tested for "contacts" between conductors and fixtures, for " short circuits,"...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...to condensation within the pipes must be guarded against by sealing the upper end of the fixture. 6. No combination fixture in which the conductors are...inside pipe and the outside casing will be approved. 7. Each fixture must be tested for possible " contacts " between conductors and fixture, and for "...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...to condensation within the pipes must be guarded against by sealing the upper end of the fixture. 6. No combination fixture in which the conductors are...Inside pipe and the outside casing will be approved. 7. Each fixture must be tested for possible "contacte" between conductors and fixture, and for "short-circuit«...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...to condensation within the pipes must be guarded against by sealing the upper end of the fixture. 6. No combination fixture in which the conductors are...inside pipe and the outside casing will be approved. 7. Each fixture must be tested for possible " contacts "' between conductors and fixture, and for "...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...abraded by the pressure of the fastenings or motion of the fixture. d. All conductors for fixture-work must have a waterproof insulation that is durable...conductors and fixtures, for "short circuits," and for groundconnections before the fixture is connected to its supplyconductors. i. Ceiling-blocks of fixtures...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...abraded, and must not in any case be smaller than No. 18 B. & S., No. 2o BWG , No. 2 ESG e. All burs or fins must be removed before the conductors are...than one-fourth inch between the inside pipe and the outsike casing will be approved. h. Each fixture must be tested for " contacts " between conductors...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...ceiling. b. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. "if. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...ceiling. t>. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 514 стор.
...condensation within the pipes should be guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are...inside pipe and the outside casing will be approved. c. Must be tested for "contacts" between conductors and fixture, for "short circuits," and for ground...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...celling. b. Must have all burs, or fins, removed before the conductois are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...