with condensing water at degrees

j Fahr. } {Cent, j

, feed pump(s) of standard PumpM^na

manufacture (each) having ample capacity to feed — h. p. in boilers.

feed-water heater(s) [and puri- a^f£*'

fier(s)] of standard manufacture (each) ^3^erif.nd having ample capacity for—h. p. in boilers.

(Specify character of water to be used, and whether exhaust steam is to be used for any other purpose than heating feedwater.)

[ocr errors][merged small]

A gauge board of shall be erected 222^^

in , and the following instruments

mounted thereon: . Connections

shall be made between these instruments and in the following manner .

223. Painting. (Ag reqUired.)

224partaew<u Such renewal parts as it is advisable to have on hand shall be furnished, a list of same to be added hereto.

225. summary. (gee Note: p. 52, sec. 27.)

Each bidder shall fill out completely the following summary:

Number of boilers . . .

Rated horse-power . . — —

Kind ..... .

Diameter of shell . . .

Length of shell ....

Number of tubes . . .

Diameter of tubes . . .

Heating surface . . .

Tensile strength of steel . .

Working pressure . . .

Testing pressure ... .

Outside dimensions of setting .

Number of condensers . .

Kind .....

Capacity of each . . .

Number of pumps . . .

Kind

Capacity of each Number of heaters Kind

Capacity of each

RULES AND REQUIREMENTS

OF THE

NATIONAL BOARD OF FIEE UNDERWRITERS FOR THE INSTALLATION OF WIRING AND APPARATUS FOR ELECTRIC LIGHT AND POWER AS RECOMMENDED BY THE UNDERWRITERS' NATIONAL ELECTRIC ASSOCIATION.

EDITION OF JAN. 1, 1895.

The use of wire ways for rendering concealed wiring permanently accessible, is most heartily endorsed and recommended; and this method of accessible concealed construction is advised for general use.

Architects are urged, when drawing plans and specifications, to make provision for the channeling and pocketing of buildings for electric light or power wires, and in specifications for electric gas lighting to require a two-wire circuit, whether the building is to be wired for electric lighting or not, so that no part of the gas fixtures or gas piping be allowed to be used for the gas lighting circuit.

CENTRAL STATIONS.
Class A.

FOR LIGHT OR POWER. These Rules also apply to Dynamo Rooms in Isolated Plants, connected with or detached from building's used for other purposes; also to all varieties of apparatus therein of both high and low potential.

1. Generators:

a. Must be located in a dry place.

b. Must be insulated on floors or base-frames, which must be kept filled, to prevent absorption of moisture, and also kept clean and dry.

c. Must never be placed in a room where any hazardous process is carried on, more in places where they would be exposed to inflammable gases, or flyings, or combustible material.

d. Must each be provided with a waterproof covering.

2. Care And Attendance:

A competent man must be kept on